๐”– Bobbio Scriptorium
โœฆ   LIBER   โœฆ

Stability-indicating liquid chromatographic determination of etoposide and benzyl alcohol in injectable formulations

โœ Scribed by B. J. Floor; A. E. Klein; N. Muhammad; D. Ross


Publisher
John Wiley and Sons
Year
1985
Tongue
English
Weight
411 KB
Volume
74
Category
Article
ISSN
0022-3549

No coin nor oath required. For personal study only.


๐Ÿ“œ SIMILAR VOLUMES


Stability-indicating analysis of injecta
โœ R. Roman; C. H. Yates; J. F. Millar; J. O'Neill; J. S. Zweig ๐Ÿ“‚ Article ๐Ÿ“… 1979 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 463 KB ๐Ÿ‘ 1 views

A method was developed for the analysis of testosterone 17-enanthate 3-benzilic acid hydrazone, 17-beta-estradiol 3,17-dienanthate, and estradiol benzoate combinations dissolved in an oily vehicle. Testosterone 17-enanthate 3-benzilic acid hydrazone was separated from the other drugs and vehicle com

Stability-indicating high-performance li
โœ Sigmund M. Waraszkiewicz; E. A. Milano; R. Dirubio ๐Ÿ“‚ Article ๐Ÿ“… 1981 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 465 KB ๐Ÿ‘ 1 views

A reversed-phase, high-performance liquid chromatographic (HPLC) procedure, which is specific and quantitative for lidocaine hydrochloride, epinephrine, and methylparaben, was developed for the analysis of lidocaine hydrochloride and lidocaine hydrochloride with epinephrine solutions for injection.

Stability indicating reversed-phase high
โœ Zeinab A. El-Sherif; Badr El-Zeany; Ola M. El-Houssini; Mohamed S. Rashed; Hassa ๐Ÿ“‚ Article ๐Ÿ“… 2004 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 95 KB ๐Ÿ‘ 2 views

## Abstract Two sensitive and reproducible methods were developed and validated for the determination of ziprasidone (ZIP) in the presence of its degradation products in pure form and in pharmaceutical formulations. The ๏ฌrst method was based on reversedโ€phase highโ€performance liquid chromatography

Rapid, stability-indicating, high-pressu
โœ D. R. Heidemann ๐Ÿ“‚ Article ๐Ÿ“… 1979 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 294 KB

Theophylline, guaifenesin, and benzoic acid were determined by reversed-phase high-pressure liquid chromatography without interference from active and/or vehicle decomposition. A degradation product of sucrose, 5-hydroxymethylfurfural, can be identified and quantified in liquid samples simultaneousl

Determination of rupatadine in pharmaceu
โœ Daniele Rubert Nogueira; Maximiliano da Silva Sangoi; Lucรฉlia Magalhรฃes da Silva ๐Ÿ“‚ Article ๐Ÿ“… 2008 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 337 KB ๐Ÿ‘ 1 views

## Abstract A stabilityโ€indicating MEKC was developed and validated for the analysis of rupatadine in tablet dosage forms, using nimesulide as internal standard. The MEKC method was performed on a fusedโ€silica capillary (50 ฮผm id; effective length, 40 cm). The BGE consisted of 15 mM borate buffer a