Stability-indicating assay of acetaminophen in an effervescent tablet by ion-pair high-performance liquid chromatography
โ Scribed by F. J. Sena; J. T. Piechocki; K. L. Li
- Publisher
- John Wiley and Sons
- Year
- 1979
- Tongue
- English
- Weight
- 192 KB
- Volume
- 68
- Category
- Article
- ISSN
- 0022-3549
No coin nor oath required. For personal study only.
โฆ Synopsis
A stability-indicating analytical method is described for determining acetaminophen and its degradation product, p-aminophenol, in an affervescent tablet. Tablets assayed by ion-pair high-performance reversed-phase liquid partition chromatography required no sample cleanup. The method applied to tablets containing 325 mg of acetaminophen yielded an average recovery of 99.6% with a relative standard deviation of 0.70% (n = 10). As little as 0.005% p-aminophenol could be detected.