Magnetization transfer and finite radiofrequency (RF) pulses affect the steady state of balanced steady state free precession. As quantification of transverse relaxation (T 2 ) with driven equilibrium single pulse observation of T 2 is based on two balanced steady state free precession acquisitions,
SSFP signal with finite RF pulses
β Scribed by Oliver Bieri; Klaus Scheffler
- Publisher
- John Wiley and Sons
- Year
- 2009
- Tongue
- English
- Weight
- 762 KB
- Volume
- 62
- Category
- Article
- ISSN
- 0740-3194
No coin nor oath required. For personal study only.
β¦ Synopsis
Abstract
The theoretical description of steady state free precession (SSFP) sequences is generally well accepted and unquestioned, although it is based on instantaneously acting radiofrequency (RF) pulses. In practice, however, all excitation processes are finite, thereby questioning the overall validity of the common SSFP signal description for use with finite RF pulses. In this paper, finite RF pulse effects on balanced SSFP signal formation are analyzed as a function of the RF time, the pulse repetition time, the flip angle (Ξ±) and relaxation times (T~1,2~). The observed signal modulations from finite RF pulses (compared to infinitesimal ones) can range from only a few percent (for RF time/pulse repetition time βͺ 1, Ξ± βͺ 90Β°, T~2~/T~1~ βΌ 1) to over 10% (for RF time/pulse repetition time βͺ 1, Ξ± βΌ 90Β°, T~2~/T~1~ βͺ 1) and may even exceed 100% in the limit of RF time/pulse repetition time β 1 (for Ξ± βΌ 90Β°, T~2~/T~1~ βͺ 1). As a result, a revision of SSFP signal theory is indicated not only for reasons of completeness but also seems advisable, e.g., for all quantitative SSFP methods. A simple modification for the common balanced SSFP equation is derived that provides an accurate framework for SSFP signal description over a wide variety of practical and physiologic parameters. Magn Reson Med, 2009. Β© 2009 WileyβLiss, Inc.
π SIMILAR VOLUMES
## Abstract Magnetic resonance angiography (MRA) was performed by using RF pulses designed to excite a limited spatial extent in two orthogonal directions. The restriction in the second spatial dimension can be used to increase inflow enhancement and to improve small fieldβofβview imaging. A rectan
## Abstract Rapid imaging can be performed in the magnetic field of low homogeneity using 180Β° RF pulses instead of gradient reversals to form a series of differently phaseβencoded echoes. A modified version of Οβpulsed EPI which samples the data in two complementary shots was designed. Its advanta
## Abstract An inherent problem of conventional chemical shift imaging is signal contamination into adjacent voxels. This is especially severe in proton spectroscopy of the central nervous system, where the lipid signal from the skull is several orders of magnitude higher than the metabolite resona
## Abstract A method for simultaneous multislice imaging is presented that uses a multislice RF pulse that imparts a different linear phase profile to each slice. During readout, slices are unaliased by using extra sliceβselect gradient lobes, which rephase and dephase individual slices one at a ti