Chemical shift imaging with phase-encoding RF pulses
✍ Scribed by J. Hennig
- Publisher
- John Wiley and Sons
- Year
- 1992
- Tongue
- English
- Weight
- 530 KB
- Volume
- 25
- Category
- Article
- ISSN
- 0740-3194
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
An inherent problem of conventional chemical shift imaging is signal contamination into adjacent voxels. This is especially severe in proton spectroscopy of the central nervous system, where the lipid signal from the skull is several orders of magnitude higher than the metabolite resonances from the brain. The reason for the contamination lies in the fact that the distribution of spins does not coincide with the discrete sampling matrix of the discrete Fourier transformation if a continuous phase‐encoding scheme using magnetic field gradients is being used. This problem can be overcome if phase encoding is performed by appropriately phase‐modulated RF pulses. It is demonstrated that contamination free spectra can be acquired from voxels immediately adjacent to the skull. Using small voxels of 1 × 1 × 2‐ml regional variations of N‐acetyl aspartate in the cerebellum of patients with oligopontine cerebellar atrophy could be observed. © 1992 Academic Press, Inc.
📜 SIMILAR VOLUMES
## Abstract Magnetic resonance angiography (MRA) was performed by using RF pulses designed to excite a limited spatial extent in two orthogonal directions. The restriction in the second spatial dimension can be used to increase inflow enhancement and to improve small field‐of‐view imaging. A rectan
## Abstract A method for simultaneous multislice imaging is presented that uses a multislice RF pulse that imparts a different linear phase profile to each slice. During readout, slices are unaliased by using extra slice‐select gradient lobes, which rephase and dephase individual slices one at a ti
## Abstract The ability to generate in vivo maps of lactate may have significant diagnostic utility in staging and treatment planning of a wide variety of cancers. The double selective multiple quantum filter technique (SelMQC) has been shown to be effective for nonlocalized detection of lactate wi
it places relatively high demands on B 0 -gradient hardware The sensitivity of magnetic resonance imaging (MRI) exand RF power deposition. periments can be enhanced with surface coil (1) signal detec-Here we propose an alternative method for multislice imtion. However, the high B 1 inhomogeneity of
## Abstract Two fat‐suppressed three‐dimensional gradient echo pulse sequences, FLASH and DESS (__D__ouble __E__cho in Steady‐State), that have significantly reduced scan time compared with conventional chemical shift fat‐suppression sequences are presented. This fat‐suppression technique is based