𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Spectral matching quantitative open-path fourier-transform infrared spectroscopy

✍ Scribed by Linda Ingling; Thomas L. Isenhour


Publisher
John Wiley and Sons
Year
1999
Weight
139 KB
Volume
3
Category
Article
ISSN
1086-900X

No coin nor oath required. For personal study only.

✦ Synopsis


Open-path Fourier-transform infrared spectroscopy (OP-FTIR) provides a rapid method of measuring concentrations of volatile organic compounds (VOCs) in environmental settings. The advantages of OP-FTIR are the speed of data collection and the absence of sample handling. The quantitative difficulties with OP-FTIR include variation in source intensity caused by moving the source or instrument, rapid change in temperature, low intensity of passive sources, and changes in path conditions such as humidity and the presence of interfering compounds. These difficulties are the major obstacles in using OP-FTIR quantitatively. We are developing a method that has shown promise in combating source variability, the difficulty in obtaining reference spectra, and the problems with passive sources. Reducing the resolution and graphing the intensity of the analyte peaks against a convenient reference system produces quantitative curves without subtracting background spectra. These curves can be used to determine unknown concentrations to an accuracy of 20% as long as the intensity and the general shape of the unknown sample spectrum matches a representative spectrum of the quantitative curve. We have determined sample unknowns with the use of running car engines and hot car hoods as sources. The main problem still to be studied is that accurate concentration determination requires a good match between the temperature profiles of the quantitative curve spectra and the sample spectrum. Future studies will involve the relationship between source temperature and spectral shape, source temperature and absorption peak magnitude, and the effect of distance from the source to the instrument on spectral shape and peak magnitude.


πŸ“œ SIMILAR VOLUMES


Effects of resolution, spectral window,
✍ Brian K. Hart; R. James Berry; Peter R. Griffiths πŸ“‚ Article πŸ“… 1999 πŸ› John Wiley and Sons βš– 205 KB

The performance of CLS, PLS-2, and PLS-1 on calibration/validation sets of mixtures of five short-chain alcohols was examined as a function of resolution, spectral window, and type of background single beam to determine the feasibility of achieving automated calibrations for open-path Fourier-transf

Quantitative Analysis of Norditerpenoid
✍ Dale R. Gardner; Gary D. Manners; Michael H. Ralphs; James A. Pfister πŸ“‚ Article πŸ“… 1997 πŸ› John Wiley and Sons 🌐 English βš– 167 KB πŸ‘ 2 views

A Fourier transform infrared (FT-IR) spectroscopic method for measuring norditerpenoid alkaloids in larkspurs was developed. Alkaloids were isolated from dry plant material using a simplified extraction procedure and quantitated using FT-IR. Calibration of the method was made from selected larkspur

Quantitative determination of peroxide v
✍ G. Setiowaty; Y. B. Che Man; S. Jinap; M. H. Moh πŸ“‚ Article πŸ“… 2000 πŸ› John Wiley and Sons 🌐 English βš– 71 KB πŸ‘ 2 views

A simple and rapid quantitative method to determine peroxide value (PV) of palm olein has been developed using transmittance Fourier transform (FT) IR spectroscopy. Palm olein was oxidized and blended with unoxidized palm olein to generate samples with PVs in the range 3.52-9.86. These samples were

Determination of exact absorption behavi
✍ Brogly, Maurice; Bistac, Sophie; Schultz, Jacques πŸ“‚ Article πŸ“… 1997 πŸ› John Wiley and Sons 🌐 English βš– 318 KB πŸ‘ 2 views

In the present work we demonstrate that infrared absorption frequencies and band shapes of poly(methylmethacrylate) (PMMA) homopolymers vary strongly with the type of spectra recorded. The reason is that, in general, any measured optical quantity, such as absorption, transmittance or reΓ‘ectance, is