𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Spatio-temporal bandwidth-based acquisition for dynamic contrast-enhanced magnetic resonance imaging

✍ Scribed by Sumati Krishnan; Thomas L. Chenevert


Publisher
John Wiley and Sons
Year
2004
Tongue
English
Weight
640 KB
Volume
20
Category
Article
ISSN
1053-1807

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

Purpose

To develop a k‐space formalism that provides a rationale for the design of variable‐rate acquisition schemes for dynamic contrast‐enhanced magnetic resonance imaging (DCE‐MRI).

Methods and Materials

The formalism, termed spatio‐temporal bandwidth‐based (STBB) analysis, is demonstrated using a priori modeling of object and enhancement characteristics typically observed in DCE‐MRI of breast tumors. A temporally enhancing lesion is considered as a two‐dimensional (2D) space‐time object that possesses a corresponding spatio‐temporal (k~y~‐k~t~) energy spectrum. The k~y~‐k~t~ space is segmented based on a threshold such that the total spectral energy in a finite number of k‐space samples, constrained by the imaging experiment, is maximized. This thresholded map contains a set of spatial and corresponding temporal sampling prescriptions. These prescriptions are used in designing an acquisition scheme that is adequate for a range of contrast‐enhancing breast lesions. The STBB scheme is compared to an equivalent “keyhole” acquisition, in terms of quantification of enhancement rate, K^trans^, extracellular volume fraction, ν~e~, and spatial fidelity. We chose object sizes Npix = 2, 5, 10, 15, 20, and 30 pixels and enhancement rates K^trans^ = 1.5, 1, 0.6, 0.4, 0.3, and 0.2 minute^–1^, and ν~e~ was held at 0.3.

Results

The STBB scheme results in more accurate estimation of the rate and extracellular volume fraction parameters when the object size is small (two and five pixels) and the enhancement rates are rapid (1.5 and 1 minute^–1^), compared to the keyhole acquisition. The STBB scheme provides higher spatial fidelity for very small objects. For large object and slow enhancements, the keyhole and STBB scheme perform comparably.

Conclusion

We have demonstrated an intuitive formalism applicable to DCE‐MRI for a set of targeted/anticipated dynamic events as well as spatial features. This formalism can be extended to any dynamic imaging condition, and a corresponding variable‐rate acquisition scheme can be designed. J. Magn. Reson. Imaging 2004;20:129–137. © 2004 Wiley‐Liss, Inc.


📜 SIMILAR VOLUMES


Dynamic contrast-enhanced magnetic reson
✍ Isabelle Thomassin-Naggara; Emile Daraï; Charles A Cuenod; Roman Rouzier; Patric 📂 Article 📅 2008 🏛 John Wiley and Sons 🌐 English ⚖ 626 KB

## Abstract ## Purpose To evaluate the utility of dynamic contrast enhancement (DCE) MRI for distinguishing among benign, borderline and invasive epithelial ovarian tumors. ## Materials and Methods We analyzed preoperative MRI studies of 37 patients with ovarian epithelial tumors (10 benign, 11

Algorithms for calculation of kinetic pa
✍ Mark A. Horsfield; Bruno Morgan 📂 Article 📅 2004 🏛 John Wiley and Sons 🌐 English ⚖ 261 KB

## Abstract ## Purpose To quantify the errors involved in calculating dynamic parameters (__K__^trans^ and __v__~__e__~) from dynamic contrast‐enhanced magnetic resonance imaging (DCE‐MRI) scans, and to develop alternative analyses to improve accuracy or increase processing speed. ## Materials an

Efficient method for calculating kinetic
✍ Kenya Murase 📂 Article 📅 2004 🏛 John Wiley and Sons 🌐 English ⚖ 105 KB

## Abstract It has become increasingly important to quantitatively estimate tissue physiological parameters such as perfusion, capillary permeability, and the volume of extravascular‐extracellular space (EES) using __T__~1~‐weighted dynamic contrast‐enhanced MRI (DCE‐MRI). A linear equation was der

A pharmacokinetic model for quantitative
✍ Mehmet Bilgen; Ponnada A. Narayana 📂 Article 📅 2001 🏛 John Wiley and Sons 🌐 English ⚖ 243 KB

## Abstract A multicompartment pharmacokinetic model was proposed to quantitatively describe the distribution of the contrast agent gadopentetate‐dimeglumine (Gd) in an experimental spinal cord injury (SCI). Concentration of Gd was measured in different compartments with in vivo dynamic contrast‐en

Implementation of a rapid inversion-prep
✍ Daniel Prochnow; Dirk Beyersdorff; Carsten Warmuth; Matthias Taupitz; Ole Gemein 📂 Article 📅 2005 🏛 Elsevier Science 🌐 English ⚖ 423 KB

The first step in quantitative pharmacokinetic modeling is to determine the arterial input function (AIF) by deriving the contrast medium (CM) concentration from an appropriate imaging sequence by monitoring changes in either the amplitude or the phase signal of an accommodative artery. The bolus pa