𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Single-Shot Fourier Velocity Imaging

✍ Scribed by F. Hennel; Z. Sulek; A. Jasinski


Book ID
102591226
Publisher
Elsevier Science
Year
1993
Tongue
English
Weight
276 KB
Volume
102
Category
Article
ISSN
1064-1858

No coin nor oath required. For personal study only.


📜 SIMILAR VOLUMES


Single-shot curved slice imaging
✍ Jochimsen, T 📂 Article 📅 2002 🏛 Springer 🌐 English ⚖ 201 KB

The feasibility of imaging a curved slice with a single-shot technique so that the reconstructed image shows an un-warping of the slice is examined. This could be of practical importance when the anatomical structures of interest can be more efficiently covered with curved slices than with a series

Single-shot ADC imaging for fMRI
✍ Allen W. Song; Hua Guo; Trong-Kha Truong 📂 Article 📅 2007 🏛 John Wiley and Sons 🌐 English ⚖ 767 KB

## Abstract It has been suggested that apparent diffusion coefficient (ADC) contrast can be sensitive to cerebral blood flow (CBF) changes during brain activation. However, current ADC imaging techniques have an inherently low temporal resolution due to the requirement of multiple acquisitions with

“One-shot” velocity microscopy: NMR imag
✍ Yang Xia; Paul T. Callaghan 📂 Article 📅 1992 🏛 John Wiley and Sons 🌐 English ⚖ 986 KB

## Abstract The use of the pulsed gradient spin‐echo sequence in NMR microscopy enables the measurement of molecular translational motion and simultaneous construction of velocity and self‐diffusion images, a technique that has been termed dynamic NMR microscopy. In this method the PGSE contrast gr

Single-shot half-fourier RARE sequence w
✍ Yoshiharu Ohno; Koichi Oshio; Hidemasa Uematsu; Masashi Nakatsu; Warren B. Gefte 📂 Article 📅 2004 🏛 John Wiley and Sons 🌐 English ⚖ 200 KB

## Purpose: To improve the image quality of pulmonary magnetic resonance (mr) imaging using an ultra-short inter-echo spacing half-fourier single shot rapid acquisition with relaxation enhancement (usha-rare) sequence. ## Materials and methods: Pulmonary mr images were acquired by usha-rare seque

Half-Fourier acquisition single-shot tur
✍ Dean Tyrell; Feroze Mohamed; Constantinos Pavlides; Steven Kutalek; Charles Mulh 📂 Article 📅 2001 🏛 John Wiley and Sons 🌐 English ⚖ 264 KB

## Abstract Magnetic resonance (MR) imaging with multi‐planar, gated Half‐Fourier Acquisition Single‐Shot Turbo Spin‐Echo (HASTE) imaging was performed to evaluate a woman with dysrhythmia. MR examination for right ventricular dysplasia revealed a Morgagni hernia. The HASTE images depicted well the