𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Single-shot curved slice imaging

✍ Scribed by Jochimsen, T


Book ID
104390824
Publisher
Springer
Year
2002
Tongue
English
Weight
201 KB
Volume
14
Category
Article
ISSN
0968-5243

No coin nor oath required. For personal study only.

✦ Synopsis


The feasibility of imaging a curved slice with a single-shot technique so that the reconstructed image shows an un-warping of the slice is examined. This could be of practical importance when the anatomical structures of interest can be more efficiently covered with curved slices than with a series of flat planes. One possible example of such a structure is the cortex of the human brain. Functional imaging would especially benefit from this technique because several planar images can be replaced by a few curved slice images. A method is introduced that is based on multidimensional pulses to excite the desired curved slice profile. A GRASE imaging sequence is then applied that is tailored to the k-space representation of the curved slice. This makes it possible to capture the in-plane information of the slice with a single-shot technique. The method presented is limited to slices that are straight along one axis and can be approximated by a polygon. Reconstruction is performed using a simple numeric Fourier integration along the curved slice. This leads to an image that shows the desired un-warped representation of the slice. Experimental results obtained with this method from healthy volunteers are presented and demonstrate the feasibility of the proposed technique.


📜 SIMILAR VOLUMES


STEAM-Burst: A single-shot, multi-slice
✍ Yannick Crémillieux; Claudia A. Wheeler-Kingshott; André Briguet; Dr. Simon J. D 📂 Article 📅 1997 🏛 John Wiley and Sons 🌐 English ⚖ 793 KB

## Abstract The stimulated‐echo acquisition mode‐Burst sequence is a single‐shot, multi‐slice imaging technique that does not involve rapid gradient switching. A Burst excitation pulse train is followed by a 90° hard pulse and, after a mixing time, by a 90° slice‐selective pulse. A read gradient re

Single-shot ADC imaging for fMRI
✍ Allen W. Song; Hua Guo; Trong-Kha Truong 📂 Article 📅 2007 🏛 John Wiley and Sons 🌐 English ⚖ 767 KB

## Abstract It has been suggested that apparent diffusion coefficient (ADC) contrast can be sensitive to cerebral blood flow (CBF) changes during brain activation. However, current ADC imaging techniques have an inherently low temporal resolution due to the requirement of multiple acquisitions with

Single-Shot GRASE Imaging without Fast G
✍ Koichi Oshio; David A. Feinberg 📂 Article 📅 1992 🏛 John Wiley and Sons 🌐 English ⚖ 306 KB

## Abstract Based on the CPMG sequence, gradient‐ and spin‐echo (GRASE) echo train length is limited by T2 decay rather than the T2^\*^ decay and phase error in echo‐planar techniques, permitting a longer image acquisition period. An ultrafast GRASE sequence, utilizing a single excitation, generate

CSF-suppressed quantitative single-shot
✍ K. K. Kwong; R. C. McKinstry; D. Chien; A. P. Crawley; J. D. Pearlman; B. R. Ros 📂 Article 📅 1991 🏛 John Wiley and Sons 🌐 English ⚖ 463 KB

## Abstract A CSF‐suppressed, inversion‐recovery (IR) single‐shot diffusion sequence was used to demonstrate that CSF makes a dominant contribution to the nonmonoexponential diffusion decay behavior observed in cortical gray matter brain tissue. © 1991 Academic Press, Inc.