A spectrophotometric flow-injection method based on a diazo-coupling reaction is proposed for the simultaneous determination of nitrite and nitrate. Nitrate is reduced to nitrite by using a reductor column which is formed by filling part of the sample loop with copperized cadmium. The flow system pr
Simultaneous flow injection determination of nitrate and nitrite in water by gas-phase chemiluminescence
โ Scribed by Toyoaki Aoki; Muneki Wakabayashi
- Publisher
- Elsevier Science
- Year
- 1995
- Tongue
- English
- Weight
- 396 KB
- Volume
- 308
- Category
- Article
- ISSN
- 0003-2670
No coin nor oath required. For personal study only.
โฆ Synopsis
A reagent-injection flow injection procedure for the determination of nitrate and nitrite in water by reduction to NO followed by a membrane separation process and chemiluminescence detection, with air-stripping, is proposed. Microporous PTFE was used as a membrane to transfer NO to the gas phase after reducing nitrate and nitrite with Ti(III) and nitrite alone by iodide in acidic media. Chemiluminescence (CL) peak height signals produced by the reaction of NO with ozone were linearly proportional to concentrations from 5 pg N/I as nitrate and 3 pg N/l as nitrite to around 1 mg N/I. The relative standard deviation (n = 5) was 1.2% at 0.70 mg N/l nitrate and 1.4% at 0.28 mg N/l nitrite. The response time from injecting the reducing agent until the signal reached a peak was 1.0 min. In the presence of nitrite, nitrate could be determined from the difference between the CL intensity in the Ti(II1) and iodide systems.
๐ SIMILAR VOLUMES
cGMP) which promotes vascular smooth muscle relax-An automated method for the simultaneous determiation. ## nation of nitrite and nitrate in biological samples by Many investigators have used L-arginine analogs for using a multichannel flow injection analyzer has been competitive inhibition of NO
A direct spectrophotometric method for the simultaneous determination of nitrate and nitrite by column preconcentration has been developed. Nitrate is reduced to nitrite in a copper-coated cadmium column which is then treated with azo dye reagent by column preconcentration, and the absorbance due to
The design, development, and testing of a flow-injection analysis (FIA) manifold for the simultaneous determination of two species in water samples are reported. Fluoride is determined potentiometrically, and, following on-line sample dilution and treatment, amperometric analysis of phenolics is per
The concentration of the inorganic anions nitrate and nitrite has been determined in the Guadalquivir river and the Donana National Park located in the Southwest of Spain. Reversed-phase ion pair liquid chromatography has been employed with tetrabutylammonium bromide as the counterion in the mobile