A method for the separatory determination of bile acid 3-sulfates by liquid chromatography (LC)/electrospray ionization (ESI) mass spectrometry (MS) was developed. The sulfates were characterized by an abundant pseudomolecular ion [ M Γ H ]with a doubly charged ion [ M Γ 2H ] 2-, and the ratio of th
Separatory determination of diastereomeric ibuprofen glucuronides in human urine by liquid chromatography/electrospray ionization-mass spectrometry
β Scribed by Shigeo Ikegawa; Naoaki Murao; Junji Oohashi; Junichi Goto
- Publisher
- John Wiley and Sons
- Year
- 1998
- Tongue
- English
- Weight
- 80 KB
- Volume
- 12
- Category
- Article
- ISSN
- 0269-3879
No coin nor oath required. For personal study only.
β¦ Synopsis
A method for the separatory determination of diastereomeric isomers of glucuronic acid conjugates of ibuprofen having a carboxyl group at the chiral center by liquid chromatography (LC)/electrospray ionization (ESI)-mass spectrometry (MS) has been developed. The authentic specimens of acyl glucuronides of R(Γ)-and S()-ibuprofen were chemically synthesized by the Mitsunobu reaction. In the ESI mode, the glucuronides were characterized by an abundant quasi-molecular ion [M-H] Γ , and the formation of the negative ion was markedly influenced by a drift voltage. The resolution of diastereomeric isomers was achieved on a Develosil ODS-HG-5 column with 20 mM ammonium acetate (pH 5.0):acetonitrile (5:2, v/v) as a mobile phase where diastereomers were monitored with a corresponding quasi-molecular ion. After oral administration of racemic ibuprofen, a preferential excretion of (S)-ibuprofen glucuronide into the urine was observed.
π SIMILAR VOLUMES
A method for the separation and detection of bile acid 3-glucuronides by liquid chromatography (LC)/ electrospray ionization (ESI)-mass spectrometry (MS) has been developed. On the ESI mode, glucuronides were characterized by an intense pseudo-molecular ion [M-HI-with a doubly charged ion [M-2HI2-,
The behaviour of 5-methyl-2'-deoxycytidine (m 5 dCyd, claimed to be a potential marker for leukaemia) during the electrospray process was studied. In particular, considerations concerning the effect of solution chemistry (e.g. analyte concentration, pH, etc.) on electrospray ionization mass spectra
A liquid chromatography atmospheric pressure electrospray mass spectrometry (ESI-LC/MS) system was evaluated for the identification and characterization of n-hexane conjugated metabolites (glucuronides) in untreated urine samples. Chromatography of glucuronides was obtained under ion-suppressed reve
A method based on liquid chromatography (LC) combined with electrospray ionization tandem mass spectrometry for the analysis of the frequency of formation of 8-hydroxydeoxyguanosine (8OHdGuo), a biomarker of oxidative damage to DNA, has been developed. This analytical technique has the advantage ove