๐”– Bobbio Scriptorium
โœฆ   LIBER   โœฆ

Separated treatment of time and spatial refinement using the FDTD-3D method

โœ Scribed by Francis Denanot; Christophe Guiffaut; Alain Reineix


Publisher
John Wiley and Sons
Year
2006
Tongue
English
Weight
214 KB
Volume
48
Category
Article
ISSN
0895-2477

No coin nor oath required. For personal study only.

โœฆ Synopsis


Abstract

This paper deals with spatial and time refinement using the FDTDโ€3D method. An original methodology is presented in which time refinement and spatial refinement with a ratio of two are performed in two separated stage. It aims to simplify algorithms of refinement schemes and to better control the stability and reflection. In particular, a simple timeโ€refinement scheme is proposed with stability over a long time. ยฉ 2006 Wiley Periodicals, Inc. Microwave Opt Technol Lett 48: 649โ€“655, 2006; Published online in Wiley InterScience (www.interscience.wiley.com). DOI 10.1002/mop.21434


๐Ÿ“œ SIMILAR VOLUMES


Modeling of microwave ring resonators us
โœ Elena Semouchkina; Wenwu Cao; Raj Mittra ๐Ÿ“‚ Article ๐Ÿ“… 2000 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 160 KB ๐Ÿ‘ 2 views

Scattering parameters of microstrip ring resonators with ) and without slits that are either edge or side coupled to the feedlines are simulated by the FDTD method. The strip conductors on the deยจice can either be infinitely thin or finite in thickness. The simulations predict the occurrence of reso

Numerical analysis of the relationship b
โœ Yongjin Kim; Sangseol Lee ๐Ÿ“‚ Article ๐Ÿ“… 2001 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 169 KB

## Abstract The relationship between the coupling ratio and the time delay is analyzed using the FDTD method. The FDTD method for analyzing a microstrip structure with two lines is represented. An RVS (resistive voltage source) with singleโ€point excitation and a PML with eight layers are chosen for

The impact of navigator timing parameter
โœ Elmar Spuentrup; Matthias Stuber; Renรฉ M. Botnar; Warren J. Manning ๐Ÿ“‚ Article ๐Ÿ“… 2001 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 240 KB ๐Ÿ‘ 1 views

The impact of navigator spatial resolution and navigator evaluation time on image quality in free-breathing navigator-gated 3D coronary magnetic resonance angiography (MRA), including real-time motion correction, was investigated in a moving phantom. Objective image quality parameters signal-to-nois

High temporal and spatial resolution 3D
๐Ÿ“‚ Article ๐Ÿ“… 2011 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 36 KB

Blackwell Futura Media Services designates this journal-based CME activity for a maximum of 1 AMA PRA Category 1 Credit TM . Physicians should only claim credit commensurate with the extent of their participation in the activity. Blackwell Futura Media Services is accredited by the Accreditation Co

High temporal and spatial resolution 3D
โœ Clifton R. Haider; Stephen J. Riederer; Eric A. Borisch; James F. Glockner; Roge ๐Ÿ“‚ Article ๐Ÿ“… 2011 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 561 KB

## Abstract Methods are described for generating 3D timeโ€resolved contrastโ€enhanced magnetic resonance (MR) angiograms of the hands and feet. Given targeted spatial resolution and frame times, it is shown that acceleration of about one order of magnitude or more is necessary. This is obtained by a