𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Sensitivity Optimization of Echo Times and Data Sampling Times for Spin-Echo Spectroscopy

✍ Scribed by G. Johnson; E.X. Wu


Publisher
Elsevier Science
Year
1994
Tongue
English
Weight
275 KB
Volume
105
Category
Article
ISSN
1064-1866

No coin nor oath required. For personal study only.


πŸ“œ SIMILAR VOLUMES


Measurement of Spin-Lattice Relaxation T
✍ Max S. Lin πŸ“‚ Article πŸ“… 1984 πŸ› John Wiley and Sons 🌐 English βš– 489 KB πŸ‘ 1 views

Calculation of tissue TI in double spin-echo imaging (90"-T-I 80"-2T-1 SO0) using two repetition times (6, and b2) has entailed an approximation that ignores the two 180" pulses. The theoretical consequence of the simplification is to overestimate TI with a fractional error that increases with incre

Time-to-echo optimization for spin echo
✍ Jeffry R. Alger; Julie H. Harreld; Sloane Chen; Jan Mintorovitch; David S.K. Lu πŸ“‚ Article πŸ“… 2001 πŸ› John Wiley and Sons 🌐 English βš– 262 KB

## Abstract Superparamagnetic iron oxide (SPIO) particles are used as a contrast agent in liver magnetic resonance imaging (MRI). SPIO particles exert their greatest influence on T2‐weighted MR signal intensity. The time‐to‐echo (TE) value that provides optimal contrast has not been systematically

Optimum acquisition times of two spin ec
✍ James N. Lee; Stephen J. Riederer πŸ“‚ Article πŸ“… 1986 πŸ› John Wiley and Sons 🌐 English βš– 235 KB

Spin-echo images can be synthesized at arbitrary values of echo time TEs if two images are acquired at the same repetition time and two different echo times TE1 and TE2. Depending on the value of TEs, the noise in the synthetic images can either be greater or less than the acquisition noise. This no

Correction of frequency and phase variat
✍ Yan Zhang; Stefano Marenco; Jun Shen πŸ“‚ Article πŸ“… 2007 πŸ› John Wiley and Sons 🌐 English βš– 367 KB

## Abstract As a consequence of the time‐varying magnetic field induced by eddy currents, frequency drifting occurs when the sampling window of localized spectroscopy continuously shifts. The frequency drifting and the concomitant phase variations can severely affect spectroscopy results when data

An assessment of spin-echo rotating-fram
✍ Ruth M. Dixon; Dr. Peter Styles πŸ“‚ Article πŸ“… 1993 πŸ› John Wiley and Sons 🌐 English βš– 305 KB πŸ‘ 1 views

## Abstract The rotating frame method of localized spectroscopy can be augmented by the inclusion of a refocusing pulse to enable the measurement of T~2~ relaxation times. This technique is particularly appropriate for determining short relaxation parameters due to the absence of time consuming swi

FID sampling superior to spin-echo sampl
✍ Peter R. Seevinck; Jan-Henry Seppenwoolde; Jaco J.M. Zwanenburg; Johannes F.W. N πŸ“‚ Article πŸ“… 2008 πŸ› John Wiley and Sons 🌐 English βš– 498 KB

## Abstract This work demonstrates both theoretically and experimentally that multiple gradient‐echo sampling of free induction decay (MGEFID) is superior to MGE sampling of spin echo (MGESE) for __T__‐based quantification of holmium‐loaded microspheres (HoMS). An interleaved sampling strategy was