Sensitivity and amplitude calibration of a Fourier transform 3D quadrupole ion trap mass spectrometer

✍ Scribed by Aurika Janulyte; Yves Zerega; Michel Carette; Christelle Reynard; Jacques Andre


Publisher
John Wiley and Sons
Year
2011
Tongue
English
Weight
355 KB
Volume
46
Category
Article
ISSN
1076-5174

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

With a three‐dimensional (3D) quadrupole ion trap running in a Fourier transform operating mode, the detected signal is an image of the collective motion of the confined ions. Consequently, it is assumed that the image signal is the sum of the axial trajectories of the simultaneously confined ions. The resulting frequency spectrum after Fourier transformation comprises frequency peaks at the axial secular frequencies of the confined species according to their mass/charge ratio. With a singly confined species, the maximal amplitude of the image signal is proportional to the amplitude of the secular axial frequency peak.

The matrix method is employed to express the axial trajectory sampled at the confinement field period. In that case, the expression of the image signal, as well as its maximal amplitude, is calculated as a function of the trap operating conditions and initial axial positions and axial velocities of the ions.

The initial position and velocity distributions are connected to the injection mode. With the steady ion flow injection mode (SIFIM) and an initial phase of the confinement field equal to __k__Ο€, the maximal amplitude of the image signal is proportional to either the sum of the initial axial positions or the number of confined ions and the mean value of the initial axial positions.

By simulation, amplitude fluctuation of the frequency peak is then calculated for a number of ions ranging between some tens to some thousands of ions injected by SIFIM. The peak amplitude fluctuations induced by the fluctuations of the number of ions are seven times greater than those induced by the fluctuations of the distribution of the initial axial positions. Copyright Β© 2011 John Wiley & Sons, Ltd.


πŸ“œ SIMILAR VOLUMES


Advanced Stored Waveform Inverse Fourier
✍ Vladimir M. Doroshenko; Robert J. Cotter πŸ“‚ Article πŸ“… 1996 πŸ› John Wiley and Sons 🌐 English βš– 963 KB

The stored waveform inverse Fourier transform (SWIFT) technique is used for broadband excitation of ions in an ion-trap mass spectrometer to perform mass-selective accumulation, isolation, and fragmentation of peptide ions formed by matrix-assisted laser desorptionlionization. Unit mass resolution i

Laser-induced Fluorescence of Ba+ Ions T
✍ Guo Zhong Li; Bryan A. Vining; Shenheng Guan; Alan G. Marshall πŸ“‚ Article πŸ“… 1996 πŸ› John Wiley and Sons 🌐 English βš– 528 KB

We present the design and preliminary results from a Fourier transform ion cyclotron resonance (ICR) mass spectrometer developed for the direct detection of W/visible laser-induced fluorescence of trapped, massselected, gas-phase ions. A 3 T superconducting magnet and an open-ended multi-section cyl

A quadrupole ion trap/time-of-flight mas
✍ Doroshenko, Vladimir M.; Cotter, Robert J. πŸ“‚ Article πŸ“… 1998 πŸ› John Wiley and Sons 🌐 English βš– 470 KB πŸ‘ 2 views

A matrix-assisted laser desorption/ionization-quadrupole ion trap/reΓ‘ectron time-of-Γ‘ight (MALDI-QIT/reTOF) mass spectrometer design and its operation in both normal and tandem mass spectrometric modes are described. A parabolic reΓ‘ectron was found to be capable of providing mass resolution of 5000

Solvation of acylium fragment ions in el
✍ Ziqiang Guan; Jerrold M. Liesch πŸ“‚ Article πŸ“… 2001 πŸ› John Wiley and Sons 🌐 English βš– 330 KB

## Abstract In electrospray ionization (ESI) quadrupole ion trap and Fourier transform ion cyclotron resonance mass spectrometry, certain fragment ions (e.g. acylium ions) generated either during the ion transportation process (in the source interface region) or in the ion trap are found to undergo

Selected ion accumulation of noncovalent
✍ James E. Bruce; Steven L. Van Orden; Gordon A. Anderson; Steven A. Hofstadler; M πŸ“‚ Article πŸ“… 1995 πŸ› John Wiley and Sons 🌐 English βš– 1012 KB

An electrospray ionizatiom-Fourier transform ion cyclotron resonance (ESI-FTICR) mass spectrometer has been used in conjunction with the technique of selected-ion accumulation (SIA) to investigate its utility for the study of the gas phase behavior of noncovalent complexes from solution. SIA is demo