𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Selective determination of lithium in biological fluids using flow injection analysis

✍ Scribed by G.E. Pacey; Y.P. Wu; K. Sasaki


Publisher
Elsevier Science
Year
1987
Tongue
English
Weight
587 KB
Volume
160
Category
Article
ISSN
0003-2697

No coin nor oath required. For personal study only.

✦ Synopsis


The use of flow injection analysis to automated extraction methods for the determination of lithium ion utilizing crown ethers or cryptands is demonstrated. The ion-pair extraction of cryptand 2 11, lithium, and resazurin exhibits a linear range for lithium ion of 70 ppb to 2.1 ppm. This method could tolerate up to 1000 ppm sodium ion. The chromogenic crown ether, 1-(2-hydroxy-5-nitrobnzyl)-l-aza-4,7,1O-trioxacyclododecane, exhibits a linear range for lithium ion of 0.3 to 2 ppm. A sodium ion concentration of 230 ppm can be tolerated. Both extraction systems were used in the automated determination of lithium in blood serum and urine. Both methods agreed well with the known and/or atomic absorption values. o 1987 Academic Press, Inc.


πŸ“œ SIMILAR VOLUMES


Determination of glutathione in biologic
✍ F.A.M. Redegeld; M.A.J. van Opstal; E. Houdkamp; W.P. van Bennekom πŸ“‚ Article πŸ“… 1988 πŸ› Elsevier Science 🌐 English βš– 579 KB

A sensitive and specific assay for glutathione using a recycling reaction followed by spectrophotometric detection in a flow-injection analysis system is presented. The proposed method provides specific amplification of the response to glutathione by combined use of the enzyme GSSG reductase and the

Selective flow-injection determination o
✍ CΓ‘ndido GarcΓ­a de MarΓ­a; Teresa Manzano; RocΓ­o Duarte; Angel Alonso πŸ“‚ Article πŸ“… 1995 πŸ› Elsevier Science 🌐 English βš– 778 KB

A flow-injection procedure is described for the determination of methanol based on its alcohol oxidase-catalysed conversion to formaldehyde, which is then oxidized to formic acid by NAD+ in the presence of formaldehyde dehydrogenase. The concentration of NADH produced is measured by fluorimetry. Bot

Automated Determination of Antibody Oxid
✍ C.A.C. Wolfe; D.S. Hage πŸ“‚ Article πŸ“… 1994 πŸ› Elsevier Science 🌐 English βš– 454 KB

The oxidation of antibody carbohydrate residues is a common approach used for site-specific antibody immobilization or modification. In this study a flow injection analysis system (FIA) was developed for monitoring antibody oxidation. Antibodies were oxidized with periodate and the resulting aldehyd

Improved spectrophotometric determinatio
✍ Dyer Narinesingh; Valerie A. Stoute; Gershwin Davis; Deenesh Persad; That T. Ngo πŸ“‚ Article πŸ“… 1992 πŸ› Elsevier Science 🌐 English βš– 676 KB

Mdk samples were analysed spcctrophotometncally for their lactose content usmg flow-lwectlon analysis The methodology IS based on the carmme colour that develops (Amu = 540 nm) when lactose reacts with alkahne methylamme (pH 12 7) Lactose concentrations as low as 0 6 mg ml-' can be readily detected