Analytical and experimental studies on the cool-down of vacuum insulated cryogenic transfer lines have been carried out. An expression for estimating the cool-down history is derived taking into account the gas conduction effects. Experiments were carried out for LN2 flow in glass lines. The cool-do
Nomenclature a acoustic velocity in vapour at temperature Ta, m s "1 Cp specific heat, kcal kg "1 K "l d diameter of the pipe when vents are provided on the line, m D diameter of the pipe line when vents are not provided, m (unless mentioned otherwise) gc gravitational constant 9.81 kg ms "2 kgf q K