## Abstract A fast and sensitive method for the comprehensive screening of anabolic agents and other banned doping substances using gas chromatography/tandem mass spectrometry (GC/MS/MS) with an external ionization ion trap mass spectrometer is presented. The method takes advantage of the resolving
Screening for unknown synthetic steroids in human urine by liquid chromatography-tandem mass spectrometry
✍ Scribed by Mario Thevis; Hans Geyer; Ute Mareck; Wilhelm Schänzer
- Publisher
- John Wiley and Sons
- Year
- 2005
- Tongue
- English
- Weight
- 201 KB
- Volume
- 40
- Category
- Article
- ISSN
- 1076-5174
- DOI
- 10.1002/jms.873
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
Chemically modified steroids (designer steroids), including tetrahydrogestrinone and norbolethone, pose a threat to the integrity of the sport community. These compounds have recently been detected in urine specimens from athletes, resulting in temporary or permanent suspension from amateur and/or professional competition. Triple quadrupole mass spectrometers enable doping control laboratories to screen for unknown, anabolic, androgenic steroids utilizing precursor ion scans. On the basis of common dissociation patterns of steroids with common structural features, characteristic product ions were selected to serve as diagnostic markers for previously unidentified drugs or drug metabolites in human urine samples. An assay was established to complement standard screening procedures. Urine specimens were enzymically hydrolyzed, partitioned into ether, concentrated, and analyzed by precursor ion scanning. Spectra from samples fortified with eight standard compounds (methyltestosterone, ethyltestosterone, 1‐testosterone, gestrinone, dihydrogestrinone, tetrahydrogestrinone, norbolethone, and propyltrenbolone) and one deuterium‐labeled analog (d~4~‐tetrahydrogestrinone) at 50 ng/ml of urine, had precursor ion peaks other than those from common endogenous steroids. Subsequent product ion scan experiments on precursor ions of peaks of unknown origin provided structural identification of the unknown compounds. Copyright © 2005 John Wiley & Sons, Ltd.
📜 SIMILAR VOLUMES
A sensitive, specific and accurate high performance liquid chromatography/ionspray-tandem mass spectrometry procedure (HPLC/MS/MS) has been developed to quantify cyclophosphamide in human urine from hospital personnel involved in drug preparation and administration of antineoplastic alkylating agent
## Abstract For the detection of anabolic steroid residues in bovine urine, a highly sensitive liquid chromatographic/electrospray ionization tandem mass spectrometric (LC/ESI‐MS/MS) method was developed using both positive and negative ionization. For four compounds the ESI mode was not sensitive
A sensitive and specific high-performance liquid chromatographic/ionspray tandem mass spectrometric (LC/ionspray MS/MS) method was developed and validated to quantitate leukotriene E, (LTE,) in human urine. This method involves solid-phase extraction with Empore membrane disks to isolate LTE, and it
## Abstract A fast and selective liquid chromatography–tandem mass spectrometric (LC/MS/MS) method for the screening of 18 diuretics and probenecid in human urine is presented. Analyses were performed on a LCQ‐Deca® instrument equipped with ESI‐interface using scan by scan polarity changing. All di