𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Scan time reduction in snapshot flash MRI

✍ Scribed by P. M. Jakob; A. Haase


Publisher
John Wiley and Sons
Year
1992
Tongue
English
Weight
364 KB
Volume
24
Category
Article
ISSN
0740-3194

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

We describe the speeding up of snapshot FLASH MRI by placing a slice selection experiment before the whole imaging sequence. In conventional snapshot FLASH slice selection is made in every projection, thus consuming a great deal of experimental time. This problem can be overcome by applying only one slice‐selective procedure before starting the imaging. The idea is to make a selective saturation of the outer volume and to interrogate the unaffected slice by a train of rapid, hard, low‐angle pulses. By this new method the measuring times of snapshot FLASH can be further reduced. Β© 1992 Academic Press, Inc.


πŸ“œ SIMILAR VOLUMES


Nonuniform Phase-Encode Distributions fo
✍ G.J. Marseille; R. de Beer; M. Fuderer; A.F. Mehlkopf; D. van Ormondt πŸ“‚ Article πŸ“… 1996 πŸ› Elsevier Science 🌐 English βš– 273 KB

This Communication concerns nonuniform omission of tions. We emphasize that the k y distributions thus obtained phase-encode values (k y ), aimed at reduction of Cartesian need not be considered as random or stochastic sampling. MRI scan times (1, 2). More precisely, it shows that a good Rather, a c

Real time monitoring of laser-induced th
✍ Peter M. Jakob; Christian Hendrich; Thomas Breitling; Achim SchΓ€fer; Astrid Berd πŸ“‚ Article πŸ“… 1997 πŸ› John Wiley and Sons 🌐 English βš– 465 KB

## Abstract Snapshot FLASH imaging has been applied to study the spatial and temporal spreading of thermal changes caused by a Holmium:YAG laser in patella cartilage __in vitro__ at 7 T. The temperature dependence of the proton resonance frequency was used to demonstrate the thermal energy depositi

Sensitivity and performance time in MRI
✍ Youssef Zaim Wadghiri; Glyn Johnson; Daniel H. Turnbull πŸ“‚ Article πŸ“… 2001 πŸ› John Wiley and Sons 🌐 English βš– 220 KB

Although shimming can improve static field inhomogeneity, local field imperfections induced by tissue susceptibility differences cannot be completely corrected and can cause substantial signal loss in gradient echo images through intravoxel dephasing. Dephasing increases with voxel size so that one

Can homogeneous preparation encoding (Ho
✍ Dominik Paul; Alex Frydrychowicz; Jens Walcher; Hans-Peter Fautz; JΓΌrgen Hennig; πŸ“‚ Article πŸ“… 2007 πŸ› John Wiley and Sons 🌐 English βš– 792 KB

## Abstract ## Purpose To evaluate time efficiency, image quality, and diagnostic value of a clinical routine homogeneous preparation encoding (HoPE) imaging protocol in different malign and inflammatory abdominal conditions. ## Materials and Methods A total of 14 healthy volunteers and 40 patie