## Abstract Mucopolysaccharidosis VII (MPS VII) is a lysosomal storage disorder characterized by a deficiency in ฮฒโglucuronidase activity, leading to systemic accumulation of poorly degraded glycosaminoglycans (GAG). Along with other morbidities, MPS VII is associated with pediatric spinal deformit
Roentgenographic and biomechanical analysis of lumbar fusions: A canine model
โ Scribed by Kevin R. Gurr; Dr. Paul C. McAfee; Karen E. Warden; Chi-Ming Shih
- Publisher
- Elsevier Science
- Year
- 1989
- Tongue
- English
- Weight
- 992 KB
- Volume
- 7
- Category
- Article
- ISSN
- 0736-0266
No coin nor oath required. For personal study only.
โฆ Synopsis
An animal model of anterior and posterior column instability was developed to allow in vivo observation of bone remodeling and arthrodesis after spinal instrumentation. Various combinations of spinal fusions and instrumentation procedures were performed after an initial anterior and posterior destabilizing lesion was created at the L5-L6 vertebral levels in 35 adult beagles. After 6 months of postoperative observation, there was improved probability of achieving a spinal fusion if spinal instrumentation had been used. All biomechanical testing was performed after removal of instrumentation to test the inherent stiffnesses and quality of the spinal fusions. The fusions performed in conjunction with instrumentation (group V = Harrington instrumentation and posterolateral fusion; group VI = Luque instrumentation and posterolateral fusion) demonstrated the greatest axial rotation stiffnesses (group V, p < .05); axial compressive stiffness (group V, p < .05); and flexural stiffness (group VI, p < .05). The results show that a spinal fusion can be more reliably achieved and will be more rigid if it is accompanied by spinal instrumentation.
๐ SIMILAR VOLUMES
## Abstract The use of CoCrMo in orthopedic surgery is not new, and CoCrMo (cobaltโchromiumโmolybdenum) is well tolerated. Nevertheless, the alloy is still considered less biocompatible than titanium. We therefore wanted to explore the biocompatibility of CoCrMo by investigating the biomechanical i
The design requirements for bioabsorbable fracture fixation devices for specific applications are as yet unknown. Therefore, a range of initial mechanical properties and degradation kinetics may provide developers with additional choices for the design of absorbable fracture fixation devices. This s
Assessment of material-induced platelet activa-lead to elevated microparticle levels. MP levels were near tion is important given that it is thought to be a major mecha-background 24 h after removal of the PVA test segment. To nism of biomaterials thrombogenicity. We monitored, by determine platelet
## Abstract Thirtyโeight cemented acetabular components that had been clinically implanted in clientโowned dogs were retrieved postmortem and analyzed for mechanical stability, volumetric wear, and articular surface damage. Comparison of the results from this study with similar studies on autopsyโr