RF safety of wires in interventional MRI: Using a safety index

✍ Scribed by Christopher J. Yeung; Robert C. Susil; Ergin Atalar


Publisher
John Wiley and Sons
Year
2001
Tongue
English
Weight
196 KB
Volume
47
Category
Article
ISSN
0740-3194

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

With the rapid growth of interventional MRI, radiofrequency (RF) heating at the tips of guidewires, catheters, and other wire‐shaped devices has become an important safety issue. Previous studies have identified some of the variables that affect the relative magnitude of this heating but none could predict the absolute amount of heating to formulate safety margins. This study presents the first theoretical model of wire tip heating that can accurately predict its absolute value, assuming a straight wire, a homogeneous RF coil, and a wire that does not extend out of the tissue. The local specific absorption rate (SAR) amplification from induced currents on insulated and bare wires was calculated using the method of moments. This SAR gain was combined with a semianalytic solution to the bioheat transfer equation to generate a safety index. The safety index (°C/(W/kg)) is a measure of the in vivo temperature change that can occur with the wire in place, normalized to the SAR of the pulse sequence. This index can be used to set limits on the spatial peak SAR of pulse sequences that are used with the interventional wire. For the case of a straight resonant wire in a tissue with very low perfusion, only about 100 mW/kg/°C spatial peak SAR may be used at 1.5 T. But for ≤10‐cm wires with an insulation thickness ≥30% of the wire radius that are placed in well‐perfused tissues, normal operating conditions of 4 W/kg spatial peak SAR are possible at 1.5 T. Further model development to include the influence of inhomogeneous RF, curved wires, and wires that extend out of the sample are required to generate safety indices that are applicable to common clinical situations. We propose a simple way to ensure safety when using an interventional wire: set a limit on the SAR of allowable pulse sequences that is a factor of a safety index below the tolerable temperature increase. Magn Reson Med 47:187–193, 2002. © 2002 Wiley‐Liss, Inc.


📜 SIMILAR VOLUMES


Ensuring safety of implanted devices und
✍ William R. Overall; John M. Pauly; Pascal P. Stang; Greig C. Scott 📂 Article 📅 2010 🏛 John Wiley and Sons 🌐 English ⚖ 528 KB

## Abstract Patients with long‐wire medical implants are currently prevented from undergoing magnetic resonance imaging (MRI) scans due to the risk of radio frequency (RF) heating. We have developed a simple technique for determining the heating potential for these implants using reversed radio fre

Prospects for safety testing: Initial co
✍ Toshio Sofuni; Takayoshi Suzuki; Makoto Hayashi 📂 Article 📅 1996 🏛 John Wiley and Sons 🌐 English ⚖ 324 KB 👁 1 views

## As an initial consideration for use of TM assays in a regulatory submission, we focus here especially on the following questions: (1) What conditions would trigger the performance of a TM assay? (2) What data set is sufficient to support a negative result? and (3) What increase in mutation freq