Reversed-phase ion-pair high-performance liquid chromatography of adriamycin and adriamycinol in rat serum and tissues
β Scribed by J.M. Gallo; C.T. Hung; D.G. Perrier
- Publisher
- Elsevier Science
- Year
- 1986
- Tongue
- English
- Weight
- 579 KB
- Volume
- 4
- Category
- Article
- ISSN
- 0731-7085
No coin nor oath required. For personal study only.
β¦ Synopsis
An ion-pair reversed-phase high-performance liquid chromatographic method is presented for the determination of adriamycin and adriamycinol concentrations in rat serum and tissues. The scheme for developing the chromatographic conditions is discussed. A good separation of adriamycinol and adriamycin was obtained by using a high sodium lauryl sulphate concentration in the mobile phase. The retention times of adriamycinol, adriamycin and daunomycin (internal standard) were less than 3 min with no interfering peaks from endogenous constituents. A protein precipitation method was used to prepare the serum and tissue samples for injection.