With the Increasing use of flexible lntracoronary stents, the likelihood of complications, Including stent misplacement, will tend to rise. We describe the successful use of three commercially available retrieval devices: the nitinol gooseneck snare, the biliary forceps, and the multipurpose basket.
## Abstract We report a case of successful transfemoral retrieval of a dislodged and mechanically distorted coronary stent from the right coronary artery in a middle age woman. The distorted stent was recovered via upsizing of her femoral arterial sheath and the use of a microsnare. The procedure w