Repair of the dura mater with processed collagen devices
✍ Scribed by Vasilios A. Zerris; Kenneth S. James; Julie B. Roberts; Eugene Bell; Carl B. Heilman
- Publisher
- John Wiley and Sons
- Year
- 2007
- Tongue
- English
- Weight
- 721 KB
- Volume
- 83B
- Category
- Article
- ISSN
- 1552-4973
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
Background: We evaluated in a canine duraplasty model how specific differences in device physicomechanical properties, porosity, and crosslinking influenced the biological performance of three processed collagen dural substitutes. Methods: Three collagen dural substitutes were studied: Dura‐Guard, DuraGen, and Durepair. The initial strength, stiffness, and suture retention force were measured using standard mechanical test methods. The relative pore sizes of each device were assessed with a scanning electron microscope. Differential scanning calorimetry was used to measure their respective collagen denaturation temperatures. The biologic response and performance of the materials were evaluated via an acute (1 month) and long‐term (3 and 6 months) canine bilateral duraplasty study. Results: The mechanical properties of Dura‐Guard and Durepair were similar to native dura. We could not quantify the mechanical properties of DuraGen because of its fragile nature. The denaturation temperature of DuraGen and Dura‐Guard differed significantly from that reported for native collagens. The denaturation temperature of Durepair was comparable with the values reported for native collagens. All three materials were tolerated well by the animals. DuraGen did not maintain its structural integrity beyond 1 month. Dura‐Guard and Durepair persisted for 6 months. Durepair was populated by fibroblasts and blood vessels, whereas Dura‐Guard was not. Conclusions: The three dural substitutes tested were found to be safe and effective in healing surgically created defects in the dura mater. Although each of these dura substitutes are composed of collagen, differences in the collagen source and processing influenced device physicomechanical properties, porosity, and the nativity of the collagen polymer. These measured differences influenced device intraoperative handling and installation as well as the post‐operative biological response, where differences in device resorption, cell penetration, vascularization, and collagen remodeling were observed. © 2007 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 2007
📜 SIMILAR VOLUMES
## Abstract Human recombinant osteogenic protein‐1 (rhOP‐1) is osteoinductive. Efforts are made to develop carrier biomaterials with improved space‐keeping properties. Bovine collagen type I matrix charged with rhOP‐1 was suggested to be an advantageous device of relative liquid quality. We hypothe
An increase in the amount of membrane-bouqd DNA was found in B. subtitilia cells with UVinduced DNA repair synthesis as compared to untreated cells. It was shown that DNA repair synthesis occurred in DNA membrane complexes (DMC) formed during W-irradiation. UV-induced formation of DMC was observed i