## Abstract ## Background Conventional vascular interventional surgery (VIS) is manually performed under fluoroscopic guidance, requiring lead protection for the surgeons. In order to reduce the X‐ray irradiation, the robot has been introduced to VIS in this study. The purpose of this article is t
Remote-controlled vascular interventional surgery robot
✍ Scribed by Tianmiao Wang; Dapeng Zhang; Liu Da
- Publisher
- Wiley (Robotic Publications)
- Year
- 2010
- Tongue
- English
- Weight
- 371 KB
- Volume
- 6
- Category
- Article
- ISSN
- 1478-5951
- DOI
- 10.1002/rcs.306
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
Background
Conventional vascular interventional surgery (VIS) is manually performed under fluoroscopic guidance, requiring lead protection for the surgeons. A remote‐control vascular interventional surgery robot (VISR) which can remotely, safely and precisely perform VIS would have clear advantages.
Methods
Our robot adopts a master–slave structure. The surgeon sits at the master site, sending controlling instructions to the robot fixed at the slave site, then the robot translates these instructions into catheter motion. The robotic mechanism consists of a supporting manipulator and a catheter navigator; the former adjusts the robot's spatial position, while the latter controls the translation and rotation of the catheter. A 3D vascular model is reconstructed so that the surgeon can perform surgical planning easily. In addition, the tactile force between catheter tip and blood vessel is measured, which prevents the surgeon damaging delicate vessels. In glass model and animal experiments, the surgeon remotely controlled VISR, which inserted a catheter into predefined targets, and the robotic surgery time was measured.
Results
The robot was initially tested on a transparent glass vascular model. Under robotic manipulation, the catheter can enter an arbitrary branch of the vascular model and catheter motion can meet the requirements of clinical VIS. Then robotic surgery was performed successfully in an adult dog. Surgery time to access each of the five targets, viz. renal artery, left atrium, right atrium, left ventricle and right ventricle, was measured. Compared with conventional manual surgery, robotic surgery time is a little longer.
Conclusions
The experiments show the feasibility and safety of the VISR to facilitate navigation, position precisely and control catheters to specific regions. The VISR system offers surgeon radiation safety and minimizes surgeon‐based error. Copyright © 2010 John Wiley & Sons, Ltd.
📜 SIMILAR VOLUMES
## Abstract ## Background Obtaining the expertise to perform minimally vascular interventional surgery (VIS) requires thorough training. Previous VIS simulators have generally assumed that blood vessels are rigid. However, vascular deformation occurs unavoidably in VIS. In this study, the arterial
## Abstract ## Background Based on their experience of 150 robot‐assisted vascular reconstructions, the authors not only reflect on the current uses of the da Vinci robotic system in vascular surgery, but also discuss options for the further expansion of this cutting‐edge technology in their area
## Abstract ## Background Based on the background of minimally invasive surgery and applications of medical robots, a vascular interventional robotic system has been developed that can be used in the field of vascular intervention. ## Methods The robotic system comprises a propulsion system, an
This paper describes the development and design of a vision-based remote controlled cellular robot. Cellular robots have numerous applications in industrial problems where simple inexpensive robots can be used to perform different tasks that involve covering a large working space. As a methodology,
## Q6lO6126 Liberallratlon of the Japanese electricity market Shimazaki, M. The J. of Energy & Development, 20, (I),[79][80][81][82][83][84][85][86][87][88][89][90][91][92][93][94][95][96] The Japanese electricity industry is shackled by more regulations than other domestic industries. Electricity