## Abstract The original article to which this Erratum refers was published in IJMPR 10(2). Copyright © 2001 Whurr Publishers Ltd.
Reliability in multi-site psychiatric studies
✍ Scribed by Morven N. Leese; Ian R. White; Aart H. Schene; Maarten W.J. Koeter; Mirella Ruggeri; Luis Gaite
- Publisher
- John Wiley and Sons
- Year
- 2001
- Tongue
- English
- Weight
- 519 KB
- Volume
- 10
- Category
- Article
- ISSN
- 1049-8931
- DOI
- 10.1002/mpr.98
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
Multi‐site psychiatric studies need to take account of cultural and sometimes also linguistic differences and the reliability of the instruments used may need to be re‐established. The analysis of reliability data in these circumstances presents special problems, arising from the requirements to make the best use of all the available data and to compare reliability coefficients across sites, interpreting any differences found in terms of measurement errors and/or sample heterogeneity. Focusing on statistical issues, this paper discusses some topics that should ideally be considered when planning, conducting and analysing such studies. A number of practical examples using data from a recent European study involving the translation and cultural adaptation of five instruments used in mental health service research (the EPSILON Study) are used to illustrate the issues. Copyright © 2001 Whurr Publishers Ltd.
📜 SIMILAR VOLUMES
## Abstract The objectives of this study were to report the inter‐rater reliability of the Brief Psychiatric Rating Scale (BPRS 4.0) and the Groningen Social Disabilities Schedule (GSDS‐II) as assessed in a randomized controlled trial on the effectiveness of psychiatric day hospitals spanning five
## Abstract In the present report, estimates of test–retest and between‐site reliability of fMRI assessments were produced in the context of a multicenter fMRI reliability study (FBIRN Phase 1, www.nbirn.net). Five subjects were scanned on 10 MRI scanners on two occasions. The fMRI task was a simpl
## Abstract A gradient technique to measure electron paramagnetic resonance spectra simultaneously at several different locations is described. The technique is based on the use of point probes containing paramagnetic centers. The value of the magnetic field gradient is chosen to be sufficient to s
Administered the Hopelessness Scale to 99 criminal psychiatric inpatients, 118 general psychiatric inpatients, and 197 up er level college students. Normative data were reported for each grou . BotK of the psychiatric grou s endorsed significantly more items in the gopeless direction than did tEe c