𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Simultaneous multi-site EPR spectroscopy in vivo

✍ Scribed by Alex I. Smirnov; Shong-Wan Norby; R. B. Clarkson; Ted Walczak; Harold M. Swartz


Publisher
John Wiley and Sons
Year
1993
Tongue
English
Weight
836 KB
Volume
30
Category
Article
ISSN
0740-3194

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

A gradient technique to measure electron paramagnetic resonance spectra simultaneously at several different locations is described. The technique is based on the use of point probes containing paramagnetic centers. The value of the magnetic field gradient is chosen to be sufficient to separate the EPR signals from the different paramagnetic probes yet at the same time small enough to change only minimally the shape of individual signals. The conditions to apply this technique are considered in detail. When experimental data have a high signal‐to‐noise ratio, the lineshape distortion induced by the gradient can be corrected with the aid of a known distribution function of paramagnetic centers within the probe. The maximum entropy deconvolution algorithm is successfully applied for the correction of significantly distorted lines. The technique is experimentally tested and applied to measure the concentration of oxygen in hypertrophied rat myocardium and normal rat kidney in vivo by low frequency EPR (L‐band, 1.2 GHz). No types of EPR oxygen‐sensitive probes‐lithium phthalocyanine crystals and synthetic carbohydrate chars‐were used.


📜 SIMILAR VOLUMES


Simultaneous localized 1H STEAM/31P ISIS
✍ Robert van Sluis; Ngong M. Yongbi; Geoffrey S. Payne; Martin O. Leach 📂 Article 📅 1996 🏛 John Wiley and Sons 🌐 English ⚖ 568 KB

## Abstract A sequence for simultaneous acquisition of ^1^H STEAM and ^31^P ISIS spectra is described, and ^1^H and ^31^P spectra obtained simultaneously from the same volume of interest in both a phantom and a volunteer are presented. The STEAM and ISIS parts of the sequence use a common gradient

Simultaneous water and lipid suppression
✍ Mari A. Smith; Joseph Gillen; Michael T. McMahon; Peter B. Barker; Xavier Golay 📂 Article 📅 2005 🏛 John Wiley and Sons 🌐 English ⚖ 310 KB

## Abstract A method to achieve simultaneous water and lipid suppression is described. The key feature of the new dual suppression technique is the use of the well‐known hyperbolic secant (HS) waveform as a 90° saturation pulse. Two HS pulses with opposite frequency offsets are employed either sequ

Control characteristics of an automatic
✍ Hiroshi Hirata; Yasunori Yamaguchi; Tatsuhisa Takahashi; Zhi-Wei Luo 📂 Article 📅 2003 🏛 John Wiley and Sons 🌐 English ⚖ 152 KB

## Abstract A method for estimating the characteristics of an automatic matching control (AMC) system for in vivo electron paramagnetic resonance (EPR) spectroscopy is described. AMC is also known as automatic coupling control (ACC) and is used to compensate for perturbation due to movement of the

Stability analysis and design of automat
✍ Hiroshi Hirata; Zhi-Wei Luo 📂 Article 📅 2001 🏛 John Wiley and Sons 🌐 English ⚖ 276 KB

## Abstract Stability analysis and design of an automatic frequency control (AFC) system for in vivo continuous‐wave EPR spectroscopy is described. The open‐loop function of the feedback control system for the AFC was derived and the stability of the feedback loop systematically examined. A stabili

In vivo topical EPR spectroscopy and ima
✍ Periannan Kuppusamy; Penghai Wang; Ravi A. Shankar; Li Ma; Charles E. Trimble; C 📂 Article 📅 1998 🏛 John Wiley and Sons 🌐 English ⚖ 587 KB

## Abstract Piperidine nitroxides have considerable clinical potential, both as antioxidant therapeutic compounds and contrast agents in magnetic resonance imaging. However, their development has thus far been limited by their rapid bioreduction __in vivo__. Recently, it was reported that polynitro