✦ Synopsis


Background and Objective: To explore whether reflectance spectroscopy can differentiate normal ovary, benign neoplasms, and ovarian cancer. Study Design/Materials and Methods: Reflectance spectra (390-600 nm) were measured at three sourcedetector separations (SDS) in vivo at 64 sites in 16 patients undergoing oophorectomy. Parameters with largest statistical differences were identified. Based on these parameters algorithms were developed and evaluated. Results: Promising parameters were the reflectance intensity from 540 to 580 nm (SDS, 1.1 mm), the slope of the reflectance spectrum from 490 to 520 nm (SDS, 1.1 mm), the slope from 510 to 530 nm (SDS, 2.1 mm), and the slope from 510 to 530 (SDS, 3 mm). Average sensitivity and specificity were 86 Β± 6% and 79 Β± 5% to separate normal ovary from benign neoplasms and cancers. Average sensitivity and specificity were 86 Β± 4% and 80 Β± 8% to separate ovarian cancers from benign neoplasms and normal ovary. Conclusion: Reflectance spectroscopy should be further investigated for ovarian cancer screening.


πŸ“œ SIMILAR VOLUMES


Experimental validation of the effects o
✍ Narasimhan Rajaram; Ashwini Gopal; Xiaojing Zhang; James W. Tunnell πŸ“‚ Article πŸ“… 2010 πŸ› John Wiley and Sons 🌐 English βš– 212 KB

## Abstract ## Background Diffuse reflectance spectroscopy (DRS) uses the steady‐state diffuse reflectance measured from the tissue surface to determine absorption and scattering properties of sampled tissue. Many inverse models used to determine absorber properties have assumed a homogeneous dist

Interpreting diffuse reflectance for in
✍ Nikiforos Kollias; InSeok Seo; Paulo R. Bargo πŸ“‚ Article πŸ“… 2009 πŸ› John Wiley and Sons 🌐 English βš– 300 KB

## Abstract The measurement and quantification of skin reactions to insults involves certain assumptions about the relation between intensity of color appearance of the skin and the concentration of endogenous chromophores. The underlying assumption is that the Beer‐Lambert law is obeyed, i.e., tha

Single-voxel oversampled J-resolved spec
✍ Mark G. Swanson; Daniel B. Vigneron; Tuan-Khanh C. Tran; Napapon Sailasuta; Ralp πŸ“‚ Article πŸ“… 2001 πŸ› John Wiley and Sons 🌐 English βš– 315 KB πŸ‘ 1 views

Single-voxel J-resolved spectroscopy with oversampling in the F1 dimension was used to obtain water unsuppressed 1H spectra of in situ human prostate tissue in 40 previously untreated prostate cancer patients. Based on T2-weighted MRI and previous biopsy information, voxels were placed in regions of