The objective of this work was to investigate the performance of several coatings and surface treatments subjected to fretting fatigue with Ti-6Al-4V specimens and pads. Five coating systems were initially chosen and tested using two different fretting fatigue apparatus. The five coating systems con
Reduction of fretting corrosion of Ti-6Al-4V by various surface treatments
β Scribed by Anne M. Maurer; Dr. Stanley A. Brown; Joe H. Payer; Katharine Merritt; Jill S. Kawalec
- Publisher
- Elsevier Science
- Year
- 1993
- Tongue
- English
- Weight
- 897 KB
- Volume
- 11
- Category
- Article
- ISSN
- 0736-0266
No coin nor oath required. For personal study only.
β¦ Synopsis
Abstract
Titanium and titaniumβ6% aluminumβ4% vanadium (Tiβ6Alβ4V) are known to be biocompatible and corrosion resistant. However, there have been numerous reports of elevated tissue levels of titanium due to passive dissolution, wear, or fretting corrosion of implants. Studies were undertaken to determine whether the fretting corrosion of Tiβ6Alβ4V could be reduced by surface treatment of one or both surfaces in a fretting situation. Three different surface treatments were studied: ion implantation, physical vapor deposition nitriding, and plasma ion nitriding. The specimens used were screws fretting against the countersinks of a twoβhole plate. Fretting corrosion was assessed by weight loss, by chemical analysis of test solutions, and by scanning electron microscopy. Surface treatment of one component, the screws, resulted in reduction in the release of titanium to only 18β32% of that seen with the untreated controls. Weight loss of the untreated plates fretted against physical vapor deposition nitrided screws and plasma ion nitrided screws was reduced to 31 and 38% of the control, respectively. The weight loss of plasma nitrided screws was only 30% that of the control. Nitriding of both plates and screws resulted in a further decrease in plate weight loss and metal release. Plasma ion nitriding of both components had the most significant effect, with the weight loss and titanium release being only 11 and 2% of the control values, respectively.
π SIMILAR VOLUMES
## Abstract Stem modularity in total hip replacement introduces an additional taper joint between Tiβ6Alβ4V stem components with the potential for fretting corrosion processes. One possible way to reduce the susceptibility of the Tiβ6Alβ4V/Tiβ6Alβ4V interface to fretting is the surface modification
## Abstract Grit blasting is a common procedure of roughening surfaces to promote physical attachment of porous coatings, but it has been shown to reduce fatigue strength. Shot peening is known to increase fatigue strength by inducing compressive surface stresses; however, it is not known how subse
Earlier studies of the effect of ion implantation on wear of Ti-6Al-4V have now been extended to an examination of the effect of ion implantation on fatigue, fretting and fretting-corrosion of this alloy. Using smooth rotating-bending fatigue specimens tested in air at a frequency of 47Hz it has bee
## Abstract Corrosion has been reported at the modular interfaces of total joint replacement implants, but with conflicting theories as to the cause of such damage. The modular design itself leaves the interface susceptible to galvanic, crevice, or fretting corrosion, or a combination of the three.