Earlier studies of the effect of ion implantation on wear of Ti-6Al-4V have now been extended to an examination of the effect of ion implantation on fatigue, fretting and fretting-corrosion of this alloy. Using smooth rotating-bending fatigue specimens tested in air at a frequency of 47Hz it has bee
Mixed-metal fretting corrosion of Ti6Al4V and wrought cobalt alloy
✍ Scribed by Kawalec, Jill S. ;Brown, Stanley A. ;Payer, Joe H. ;Merritt, Katharine
- Publisher
- John Wiley and Sons
- Year
- 1995
- Tongue
- English
- Weight
- 802 KB
- Volume
- 29
- Category
- Article
- ISSN
- 0021-9304
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
Corrosion has been reported at the modular interfaces of total joint replacement implants, but with conflicting theories as to the cause of such damage. The modular design itself leaves the interface susceptible to galvanic, crevice, or fretting corrosion, or a combination of the three. The purpose of this study was to quantify the effect of material combination on fretting corrosion of orthopedic alloys. Each test specimen consisted of a two‐hole plate with spherical countersinks of a two cortical bone screws. The plates and screws were made of either Ti6Al4V or wrought cobalt–chromium–molybdenum (CCM), and were tested in all mixed‐metal and similar‐alloy combinations. Fretting corrosion experiments were conducted for 14 days in 10% calf serum, according to ASTM F897. Corrosion damage was evaluated by weight‐loss measurements, atomic absorption spectrophotometry and scanning electron microscopy analyses. The results indicated that Ti6Al4V suffered relatively severe damage when fretted against itself, as a result of adhesive galling. The extent of titanium damage was reduced considerably, however, when Ti6Al4V was fretted against wrought CCM. In contrast, there was essentially no difference in wrought CCM damage when the alloy was fretted against itself compared to fretting against Ti6Al4V. Finally, in similar‐alloy combinations, Ti6Al4V suffered more severe damage than wrought CCM. © 1995 John Wiley & Sons, Inc.
📜 SIMILAR VOLUMES
## Abstract Titanium and titanium‐6% aluminum‐4% vanadium (Ti‐6Al‐4V) are known to be biocompatible and corrosion resistant. However, there have been numerous reports of elevated tissue levels of titanium due to passive dissolution, wear, or fretting corrosion of implants. Studies were undertaken t
## Abstract It has recently been found that alloying with copper improved the inherently poor grindability and wear resistance of titanium. This study characterized the corrosion behavior of cast Ti‐6Al‐4V alloyed with copper. Alloys (0.9 or 3.5 mass % Cu) were cast with the use of a magnesia‐based
## Abstract Stem modularity in total hip replacement introduces an additional taper joint between Ti‐6Al‐4V stem components with the potential for fretting corrosion processes. One possible way to reduce the susceptibility of the Ti‐6Al‐4V/Ti‐6Al‐4V interface to fretting is the surface modification
This work studies the influence of the sintering conditions of a Ti-6Al-4V alloy on its corrosion performance. The alloy was vacuum sintered in different conditions of time and temperature. The density and microstructure (designating phase distribution) are evaluated. Corrosion resistance through el