𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Reduction of fibrinogen adsorption on PEG-coated polystyrene surfaces

✍ Scribed by Bergström, Karin ;Holmberg, Krister ;Safranj, Agneza ;Hoffman, Allan S. ;Edgell, Michael J. ;Kozlowski, Antoni ;Hovanes, Bruce A. ;Harris, J. Milton


Publisher
John Wiley and Sons
Year
1992
Tongue
English
Weight
693 KB
Volume
26
Category
Article
ISSN
0021-9304

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

Reduction of protein adsorption by coating surfaces with polyethylene glycol (PEG) is well documented. The present work has four goals related to these previous studies: first, to develop chemistry providing densely packed, covalently bound PEG on polystyrene (PS); second, to determine the ability of these modified surfaces to reject fibrinogen; third, to compare the protein‐rejecting ability of branched and linear PEGs; and fourth, to examine the utility of an ELISA‐type procedure for measuring protein adsorption. It was found that PEG‐epoxide could be readily coupled to amine groups of poly(ethy1ene imine) (PEI), which had been preadsorbed onto an oxidized PS surface. The PEG groups on branched PEGs appear to act as an excluded volume to repel proteins, similar to arguments previously raised for linear PEGs. The results of protein adsorption studies showed that fibrinogen adsorption is significantly reduced by coating polystyrene with either linear or branched PEGs of 1500 to 20,000 in molecular weight. The ELISA technique was found to be equivalent in sensitivity to radiolabeled fibrinogen for estimating adsorption levels. It is expected that PEG‐coated PS will have much utility in a variety of biomedical applications.


📜 SIMILAR VOLUMES


Adsorption of fibrinogen on modified pol
✍ Ziegler, T. F. ;Miller, M. L. 📂 Article 📅 1970 🏛 John Wiley and Sons 🌐 English ⚖ 514 KB

## Abstract The adsorption of radiotagged fibrinogen on modified polytetrafluoroethylene surfaces was measured to shed light on the reason of reduced thrombogenicity. These measurements show that when fibrinogen is adsorbed from a solution in which the molecules are in a coiled, undenatured state,

Adsorption of plasma proteins on hydroph
✍ Bagnall, Robert David 📂 Article 📅 1978 🏛 John Wiley and Sons 🌐 English ⚖ 876 KB

## Abstract The adsorption of fibrinogen from single solution and from mixed solution with albumin and γ‐globulin has been followed at the air–buffer, isooctane–buffer, and methylene iodide–buffer interfaces by the pendant drop technique. Fibrinogen is shown to form substantial coherent films on is

Transient adsorption of fibrinogen on fo
✍ Brash, J. L. ;ten Hove, P. 📂 Article 📅 1989 🏛 John Wiley and Sons 🌐 English ⚖ 768 KB

The adsorption of fibrinogen from both human whole blood and plasma to a number of "foreign" surfaces is reported. Adsorption was measured as a function of plasma or blood dilution using radioiodine labeling. We showed previously that adsorption of fibrinogen from plasma exhibits a maximum at a plas

Equilibrium adsorption of human serum al
✍ Brynda, E. ;Cepalova, N. A. ;?tol, M. 📂 Article 📅 1984 🏛 John Wiley and Sons 🌐 English ⚖ 543 KB

The adsorption of human serum albumin and human fibrinogen on flat surfaces was quantitatively determined by measuring the decrease in UV absorption in the adsorption solution. The applicability of the methacrylate), and cellophane. method is discussed for hydrophilic and hydrophobic materials. The

The Effect of Salt Concentration on Adso
✍ Orlando J. Rojas; Per M. Claesson; Dries Muller; Ronald D. Neuman 📂 Article 📅 1998 🏛 Elsevier Science 🌐 English ⚖ 170 KB

In this investigation surface force, X-ray photoelectron spectroscopy and ellipsometry techniques have been used to study the adsorption of a low-charge-density cationic polyelectrolyte on negatively charged surfaces. It is shown that the low cationicity of this polyelectrolyte induces an adsorption

Small changes in the polymer structure i
✍ Weber, Norbert ;Bolikal, Durgadas ;Bourke, Sharon L. ;Kohn, Joachim 📂 Article 📅 2004 🏛 John Wiley and Sons 🌐 English ⚖ 268 KB 👁 1 views

## Abstract Numerous studies conclude that the selective adsorption of plasma proteins on materials contacting blood or tissue affects all subsequent interactions related to the biocompatibility of artificial surfaces. However, there are only a few studies available, which clearly demonstrate that