𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Recent developments in the high-performance chelation ion chromatography of trace metals

✍ Scribed by Pavel N. Nesterenko; Phil Jones


Publisher
John Wiley and Sons
Year
2007
Tongue
English
Weight
229 KB
Volume
30
Category
Article
ISSN
1615-9306

No coin nor oath required. For personal study only.

✦ Synopsis


Chiral separation of dansyl amino acids in capillary electro


πŸ“œ SIMILAR VOLUMES


Chelating Resins and Their Applications
✍ B.S. Garg; R.K. Sharma; N. Bhojak; S. Mittal πŸ“‚ Article πŸ“… 1999 πŸ› Elsevier Science 🌐 English βš– 111 KB

Simple, sensitive, and economical methods for the determination and solid phase extraction of metal ions using chelating resins in the past 25 years have been surveyed. Chelates immobilized or loaded onto polymeric matrix and the metal ions separated and determined together with references have been

ChemInform Abstract: Recent Developments
✍ Tomaz Skapin; Gasper Tavcar; Andreja Bencan; Zoran Mazej πŸ“‚ Article πŸ“… 2010 πŸ› John Wiley and Sons βš– 15 KB πŸ‘ 2 views

## Abstract ChemInform is a weekly Abstracting Service, delivering concise information at a glance that was extracted from about 100 leading journals. To access a ChemInform Abstract of an article which was published elsewhere, please select a β€œFull Text” option. The original article is trackable v

Development of a high-sensitivity ion ch
✍ Phil Jones πŸ“‚ Article πŸ“… 1992 πŸ› Elsevier Science 🌐 English βš– 407 KB

## AhtIM The development of a novel ion chromatography method for the determmatlon of trace fluonde IS described The prmaple depends on the formation of the chromatographlcally stable AIF'+ species III the presence of excess alummmm Very high sensltMty IS achieved vnth fluorescence detectlon, grvt

Retention behavior of ions in high perfo
✍ Daignault, Louis G. ;Rillema, D. Paul πŸ“‚ Article πŸ“… 1992 πŸ› John Wiley and Sons 🌐 English βš– 204 KB

## Abstract The affects of alkali metal cations on the retention behavior of halide ions has been investigated. In general, the retention times of the anions were found to decrease as the size of the metal ion increased, although an inversion was observed for the rubidium and cesium ions. A similar

Applicability of High-Performance Ion Ch
✍ R. Giordano; L. Ciaralli; M. Ciprotti; I. Camoni; S. Costantini πŸ“‚ Article πŸ“… 1995 πŸ› Elsevier Science 🌐 English βš– 378 KB

An improved method for the determination of the systemic fungicide fosetyl-aluminum (aluminum tris(ethyl phosphonate)), in commercial formulations, via the quantitative determination of the phosphonate anion is described. The method employs HPIC using eluent suppression and conductivity detection. T