REAL-TIME NUCLEAR MAGNETIC RESONANCE CLINICAL IMAGING IN PAEDIATRICS
โ Scribed by Rzedzian, R; Mansfield, P; Doyle, M; Guilfoyle, D; Chapman, B; Coupland, R.E; Chrispin, A; Small, P
- Book ID
- 122592507
- Publisher
- The Lancet
- Year
- 1983
- Tongue
- English
- Weight
- 384 KB
- Volume
- 322
- Category
- Article
- ISSN
- 0140-6736
No coin nor oath required. For personal study only.
๐ SIMILAR VOLUMES
## Abstract A recursive algorithm suitable for functional magnetic resonance imaging (FMRI) calculations is presented. The correlation coefficient of a time course of images with a reference time series, with the mean and any linear trend projected out, may be computed with 22 operations per voxel,
## Abstract We describe a system for performing interactive MRI in real time. Using a TR/TE 7.1/ 3.5 ms sequence, the operator may alter a scan parameter and observe the effects of the alteration on the image within a few hundred milliseconds. With this system, we can interactively control the obli