𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Real-Time Functional Magnetic Resonance Imaging

✍ Scribed by Robert W. Cox; Andrzej Jesmanowicz; James S. Hyde


Publisher
John Wiley and Sons
Year
1995
Tongue
English
Weight
663 KB
Volume
33
Category
Article
ISSN
0740-3194

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

A recursive algorithm suitable for functional magnetic resonance imaging (FMRI) calculations is presented. The correlation coefficient of a time course of images with a reference time series, with the mean and any linear trend projected out, may be computed with 22 operations per voxel, per image; the storage overhead is four numbers per voxel. A statistical model for the FMRI signal is presented, and thresholds for the correlation coefficient are derived from it. Selected images from the first real‐time functional neuroimaging experiment (at 3 Tesla) are presented. Using a 50‐MHz workstation equipped with a 14‐bit analog‐to‐digital converter, each echo planar image was acquired, reconstructed, correlated, thresh‐olded, and displayed in pseudocolor (highlighting active regions in the brain) within 500 ms of the RF pulse.


πŸ“œ SIMILAR VOLUMES


Quantification of left ventricular funct
✍ Randy M. Setser; Stefan E. Fischer; Christine H. Lorenz πŸ“‚ Article πŸ“… 2000 πŸ› John Wiley and Sons 🌐 English βš– 176 KB πŸ‘ 2 views

The application of real-time magnetic resonance imaging (MRI) techniques to cardiac imaging is particularly attractive because current MR examinations of left ventricular (LV) function can be prohibitively long and are dependent on electrocardiographic triggering. We conducted a study of the minimum

Real-time display of artifact-free elect
✍ Seyed M. Mirsattari; John R. Ives; Frank Bihari; L. Stan Leung; Ravi S. Menon; R πŸ“‚ Article πŸ“… 2005 πŸ› John Wiley and Sons 🌐 English βš– 814 KB

## Abstract Simultaneous recording of electroencephalogram (EEG) and functional MRI (fMRI) or MR spectroscopy (MRS) can provide further insight into our understanding of the underlying mechanisms of neurologic disorders. Current technology for simultaneous EEG and MRI recording is limited by extens

Real-time fast strain-encoded magnetic r
✍ Grigorios Korosoglou; Amr A. Youssef; Kenneth C. Bilchick; El-Sayed Ibrahim; Alb πŸ“‚ Article πŸ“… 2008 πŸ› John Wiley and Sons 🌐 English βš– 713 KB

## Abstract ## Purpose To compare the utility of the real‐time technique fast strain‐encoded magnetic resonance imaging (fast‐SENC) for the quantification of regional myocardial function to conventional tagged magnetic resonance imaging (MRI). ## Materials and Methods Healthy volunteers (__N__ =