Abstract
Hyperpolarization of spins via dynamic nuclear polarization (DNP) has been explored as a method to non‐invasively study real‐time metabolic rocesses occurring in vivo using ^13^C‐labeled substrates. Recently, hyperpolarized ^13^C pyruvate has been used to characterize in vivo cardiac metabolism in the rat and pig. Conventional 3D spectroscopic imaging methods require in excess of 100 excitations, making it challenging to acquire a full cardiac‐gated, breath‐held, whole‐heart volume. In this article, the development of a rapid multislice cardiac‐gated spiral ^13^C imaging pulse sequence consisting of a large flip‐angle spectral‐spatial excitation RF pulse combined with a single‐shot spiral k‐space trajectory for rapid imaging of cardiac metabolism is described. This sequence permits whole‐heart coverage (6 slices, 8.8‐mm in‐plane resolution) in any plane, allowing imaging of the metabolites of interest, [1‐ ^13^C] pyruvate, [1‐ ^13^C] lactate, and ^13^C bicarbonate, within a single breathhold. Pyruvate and bicarbonate cardiac volumes were acquired, while lactate images were not acquired due to low lactate levels in the animal model studied. The sequence was demonstrated with phantom experiments and in vivo testing in a pig model. Magn Reson Med, 2010. © 2010 Wiley‐Liss, Inc.
📜 SIMILAR VOLUMES
## Abstract We show here that hyperpolarized [1‐^13^C]pyruvate can be used to detect treatment response in a glioma tumor model; a tumor type where detection of response with ^18^fluoro‐2‐deoxyglucose, using positron emission tomography, is limited by the high background signals from normal brain t
Fast chemical shift imaging (CSI) techniques are advantageous in metabolic imaging of hyperpolarized compounds due to the limited duration of the signal amplification. At the same time, reducing the acquisition time in hyperpolarized imaging does not necessarily lead to the conventional penalty in s
Measurements of the conversion of hyperpolarized [1-13 C]pyruvate into lactate, in the reaction catalyzed by lactate dehydrogenase, have shown promise as a metabolic marker for the presence of disease and response to treatment. However, it is unclear whether this represents net flux of label from py