Rapid, economical qualitative method for separation of aflatoxins B-1, B-2 & G-1, G-2 by dry column chromatography
✍ Scribed by Samuel E. Megalla
- Book ID
- 104773019
- Publisher
- Springer Netherlands
- Year
- 1983
- Tongue
- English
- Weight
- 202 KB
- Volume
- 84
- Category
- Article
- ISSN
- 0301-486X
No coin nor oath required. For personal study only.
✦ Synopsis
A good correlation of four components of aflatoxins was accomplished by using the dry column chromatography method. The decolorization process of interfering substances, by 0.01 N KOH and defatting the extract with petroleum ether yields a clean residue for DCC separation. It is clear that the dry column chromatography is a very simple and time-saving procedure for separation of aflatoxins. DCC columns are more economical than precoated 'thick layer' preparative plates and, in DCC, no large developing tanks need to be used. Hazards associated with the use of large volumes of flammable solvents are greatly reduced.