๐”– Bobbio Scriptorium
โœฆ   LIBER   โœฆ

Rapid acid digestion and simple microplate method for milk iodine determination

โœ Scribed by Mehdi Hedayati; Arash Ordookhani; Maryam Sadat Daneshpour; Fereidoun Azizi


Publisher
John Wiley and Sons
Year
2007
Tongue
English
Weight
135 KB
Volume
21
Category
Article
ISSN
0887-8013

No coin nor oath required. For personal study only.

โœฆ Synopsis


Abstract

Iodine deficiency leads to deficiency of thyroid hormones, which causes mental retardation in infant. Laboratory confirmation is important in its diagnosis. The major problems associated with the existing methods for iodine determination in milk samples are: 1) nonsafe alkaline solution; 2) harsh thermal condition; and 3) extra time required to complete various steps. In this study, a simple and rapid colorimetric method was investigated, which used acid digestion in combination with a rapid microplate reading format method to determine the total iodine content in milk. Sample digestion was done on 50โ€‰ยตL milk in metavanadate/perchloric, at 230ยฐC for 10โ€‰min. After digestion, iodine determination was based on the Sandellโ€Kolthoff reaction. The reaction results were read in 96โ€well microplates by an enzymeโ€linked immunosorbent assay (ELISA) reader. The determination range of the assay was between 2 and 40โ€‰ยตg/dL. The withinโ€run coefficient of variation percent in three levels (3, 12, and 36โ€‰ยตg/dL) ranged from 6.7 to 9.3 and betweenโ€run coefficients of variation ranged from 8.6 to 12.3%. The results obtained (n=70) by the optimized method have good correlation with the results of alkaline incineration as a reference method (n=70; r^2^=0.907; y=0.952x+1.77). Recovery tests for accuracy assessment in six levels from 6.2 to 34.2โ€‰ยตg/dL) were between 91.3 and 113%. This method has enabled us to achieve 0.12โ€‰ยตg/dL sensitivity. The results of this study show that a quick acid digestion combined with mild thermal and low sample volume with a quick reading of assay results were the main advantages of the acid digestion and microplate reading format. J. Clin. Lab. Anal. 21:286โ€“292, 2007. ยฉ 2007 Wileyโ€Liss, Inc.


๐Ÿ“œ SIMILAR VOLUMES


A rapid method for the determination of
โœ Dimitris S. Galanos; Vassilios M. Kapoulas ๐Ÿ“‚ Article ๐Ÿ“… 1966 ๐Ÿ› Elsevier Science ๐ŸŒ English โš– 516 KB

3GcJ ANALYTICA CHIhlICA ACTA I-amino -5naphthol-4-sulfonic acid (0.0640/;,) reagents were prepared as clescrilxcl by SPEI~RY:~. Pyrex tubes 25 x 200 mm and cold fingers of the appropriate size (Fig. I) wcrc used for the digestion of the samples.

Potential acidity of milk and a standard
โœ Terry, Robert Wood ๐Ÿ“‚ Article ๐Ÿ“… 1919 ๐Ÿ› Elsevier โš– 758 KB

With regard to the chemistry of the flowers themselves, little information is available in the literature. Mabeng reports a partial but non-illuminating proximate analysis of the "herb," which he speaks well of as an anthelmintic. His statement that the odor is due to a volatile oil is no doubt corr