## Abstract Simple theoretical estimates of the average, maximum, and spatial variation of the radiofrequency power deposition (specific absorption rate) during hydrogen nuclear magnetic resonance imaging are deduced for homogeneous spheres and for cylinders of biological tissue with a uniformly pe
Radiofrequency power deposition utilizing thermal imaging
✍ Scribed by Harvey Cline; Richard Mallozzi; Zhu Li; Graeme McKinnon; William Barber
- Book ID
- 102953728
- Publisher
- John Wiley and Sons
- Year
- 2004
- Tongue
- English
- Weight
- 553 KB
- Volume
- 51
- Category
- Article
- ISSN
- 0740-3194
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
Wavelength effects influence radiofrequency (RF) power deposition distributions and limit magnetic resonance (MR) medical applications at very high magnetic fields. The power depositions in spherical saline gel phantoms were deduced from proton resonance shift thermal maps at both 1.5 T and 3.0 T over a range of conductivities. Phase differences before and after RF heating were measured for both a quadrature head coil and a circular surface coil. A long echo time (TE) pulse sequence with a 3D phase unwrap algorithm provided increased thermal sensitivity. The measured thermal maps agreed with a model of eddy‐current heating by circularly polarized oscillating RF fields in a conducting dielectric sphere. At 3.0 T, thermal maps were acquired with a <0.32°C temperature rise at 4 W. Proton resonance shift thermal maps provided a measure of hot spots in very‐high‐field MR imaging (MRI), in which both the phase sensitivity and signal‐to‐noise ratio (SNR) were increased. The method provides a means of studying the heat distribution generated by RF coils excited by clinical pulse sequences. Magn Reson Med 51:1129–1137, 2004. © 2004 Wiley‐Liss, Inc.
📜 SIMILAR VOLUMES
A novel radiofrequency (rf) power calibration method for the purpose of nuclear magnetic resonance excitations based on monitoring signal phase rather than signal amplitude is described theoretically and is demonstrated experimentally. This unique method enables the determination of rf power require
Image signal-to-noise ratio and power dissipation are investigated theoretically up to 400 MHz. While the text is mathematical, the figures give insights into predictions. Hertz potential is introduced for probe modeling where charge separation cannot be ignored. Using a spherical geometry, the pote
## Abstract ## Purpose To investigate the hypothesis that the outer boundary of the hyperintense region observed in hyperacute (several minutes post‐ablation) T2 and gadolinium contrast‐enhanced (CE) T1‐weighted magnetic resonance (MR) lesion images is an accurate predictor of eventual cell death