✦ Synopsis


Abstract

Simple theoretical estimates of the average, maximum, and spatial variation of the radiofrequency power deposition (specific absorption rate) during hydrogen nuclear magnetic resonance imaging are deduced for homogeneous spheres and for cylinders of biological tissue with a uniformly penetrating linear rf field directed axially and transverse to the cylindrical axis. These are all simple scalar multiples of the expression for the cylinder in an axial field published earlier (Med. Phys. 8, 510 (1981). Exact solutions for the power deposition in the cylinder with axial (Phys. Med. Biol. 23, 630 (1978) and transversely directed rf field are also presented, and the spatial variation of power deposition in head and body models is examined. In the exact models, the specific absorption rates decrease rapidly and monotonically with decreasing radius despite local increases in rf field amplitude. Conversion factors are provided for calculating the power deposited by Gaussian and sinc‐modulated rf pulses used for slice selection in NMR imaging, relative to rectangular profiled pulses. Theoretical estimates are compared with direct measurements of the total power deposited in the bodies of nine adult males by a 63‐MHz body‐imaging system with transversely directed field, taking account of cable and NMR coil losses. The results for the average power deposition agree within about 20% for the exact model of the cylinder with axial field, when applied to the exposed torso volume enclosed by the rf coil. The average values predicted by the simple spherical and cylindrical models with axial fields, the exact cylindrical model with transverse field, and the simple truncated cylinder model with transverse field were about two to three times that measured, while the simple model consisting of an infinitely long cylinder with transverse field gave results about six times that measured. The surface power deposition measured by observing the incremental power as a function of external torso radius was comparable to the average value. This is consistent with the presence of a variable thickness peripheral adipose layer which does not substantially increase surface power deposition with increasing torso radius. The absence of highly localized intensity artifacts in 63‐MHz body images does not suggest anomalously intense power deposition at localized internal sites, although peak power is difficult to measure.


πŸ“œ SIMILAR VOLUMES


Radiofrequency power deposition utilizin
✍ Harvey Cline; Richard Mallozzi; Zhu Li; Graeme McKinnon; William Barber πŸ“‚ Article πŸ“… 2004 πŸ› John Wiley and Sons 🌐 English βš– 553 KB

## Abstract Wavelength effects influence radiofrequency (RF) power deposition distributions and limit magnetic resonance (MR) medical applications at very high magnetic fields. The power depositions in spherical saline gel phantoms were deduced from proton resonance shift thermal maps at both 1.5 T

Driven-equilibrium radiofrequency pulses
✍ C. M. J. Van Uijen; J. H. Den Boef πŸ“‚ Article πŸ“… 1984 πŸ› John Wiley and Sons 🌐 English βš– 388 KB

Driven-equilibrium pulse techniques are applied 1 . 0 NMR imaging to extend the possibilities of manipulating image contrasts in pulse sequences with a high repetition rate. In many cases the data acquisition time can be much shorter than in more conventional pulse techniques. Both calculations and

Sensitivity and Power Deposition in a Hi
✍ David I. Hoult πŸ“‚ Article πŸ“… 2000 πŸ› John Wiley and Sons 🌐 English βš– 703 KB

Image signal-to-noise ratio and power dissipation are investigated theoretically up to 400 MHz. While the text is mathematical, the figures give insights into predictions. Hertz potential is introduced for probe modeling where charge separation cannot be ignored. Using a spherical geometry, the pote