Abstract

In the pulsed arterial spin labeling (ASL) techniques EPISTAR, PICORE, and FAIR, subtraction of two images in which inflowing blood is first tagged and then not tagged yields a qualitative map of perfusion. An important reason this map is not quantitative is that there is a spatially varying delay in the transit of blood from the tagging region to the imaging slice that cannot be measured from a single subtraction. We introduce here two modifications of pulsed ASL (QUIPSS and QUIPSS II) that avoid this problem by applying additional saturation pulses to control the time duration of the tagged bolus, rendering the technique relatively insensitive to transit delays and improving the quantitation of perfusion.


📜 SIMILAR VOLUMES


Measurement of the arterial concentratio
✍ Thomas Fritz-Hansen; Egill Rostrup; Henrik B. W. Larsson; Lars Søndergaard; Poul 📂 Article 📅 1996 🏛 John Wiley and Sons 🌐 English ⚖ 710 KB

## Abstract A noninvasive method using an inversion recovery turbo‐FLASH for dynamic measurement of the arterial input function represented by the bolus passage of Gd‐DTPA in the descending aorta is presented, and the results are compared with the input function obtained by arterial blood samples.

Perfusion imaging of the human brain at
✍ Frank Q. Ye; James J. Pekar; Peter Jezzard; Jeff Duyn; Joseph A. Frank; Alan C. 📂 Article 📅 1996 🏛 John Wiley and Sons 🌐 English ⚖ 650 KB

## Abstract Single‐shot echo planar imaging (EPI) techniques have been applied, in conjunction with arterial spin tagging approaches, to obtain images of cerebral blood flow in a single axial slice in the human brain. Serial studies demonstrate that cerebral blood flow images acquired in 8 min are

Estimation of absolute myocardial blood
✍ Timothy F. Christian; Anthony H. Aletras; Andrew E. Arai 📂 Article 📅 2008 🏛 John Wiley and Sons 🌐 English ⚖ 731 KB

## Abstract ## Purpose To compare the dual‐bolus to single‐bolus quantitative first‐pass magnetic resonance myocardial perfusion imaging for estimation of absolute myocardial blood flow (MBF). ## Materials and Methods Dogs had local hyperemia of MBF in the left anterior descending (LAD) coronary

Evaluation of intraportal venous flow di
✍ Katsuyoshi Ito; Ayame Shimizu; Toshinobu Tsukuda; Katsumi Sasaki; Masahiro Tanab 📂 Article 📅 2009 🏛 John Wiley and Sons 🌐 English ⚖ 414 KB

## Abstract ## Purpose To evaluate the efficacy of subtracted MR images from two sets of unenhanced three‐dimensional (3D) MR angiography data (tag‐on and tag‐off images) acquired simultaneously during a single breath‐hold in assessing the intraportal venous flow distribution to the distal branche