## Abstract Quantitative magnetization transfer imaging (qMTI) methods are able to estimate fundamental sample parameters, such as the relative size of the solid‐like macromolecular proton pool and the spin exchange rate between this pool and the directly measured free water protons. One such metho
Quantitative imaging of magnetization transfer using an inversion recovery sequence
✍ Scribed by Daniel F. Gochberg; John C. Gore
- Publisher
- John Wiley and Sons
- Year
- 2003
- Tongue
- English
- Weight
- 237 KB
- Volume
- 49
- Category
- Article
- ISSN
- 0740-3194
No coin nor oath required. For personal study only.
✦ Synopsis
A new imaging method has been developed for quantitatively measuring magnetization transfer (MT). It uses a simple inversion recovery sequence, although one with very short (milliseconds) inversion times, and thus can be implemented on clinical imaging systems with little modification to existing pulse sequences. The sequence requires an inversion pulse with a length much longer than T(2m) (typically 10 micros) and much shorter than T(2f) (typically tens of ms) and 1/k(mf) (typically tens of ms), where T(2m) and T(2f) are the transverse relaxation times of the immobile macromolecular and free water protons, respectively, and k(mf) is the rate of MT between these populations. The resultant NMR signal is sensitive to MT when this inversion pulse affects the mobile and immobile proton pools to different degrees and by appropriate analysis of the signals obtained for different inversion times, quantitative information can be derived on the macromolecular content and exchange rates within the sample. The method has been used in conjunction with echo planar imaging to produce maps of the spatial distribution of the macromolecular content and MT rate in cross-linked bovine serum albumin. Comparisons between this method and other quantitative MT techniques are discussed.
📜 SIMILAR VOLUMES
## Abstract Multislice MR images obtained using a fast spin‐echo (FSE) readout are strongly affected by magnetization transfer (MT) effects, which will cause a decrease in the observed longitudinal relaxation times for tissues with a large bound water component. This is pertinent for FSE‐based inve
## Abstract We describe a novel imaging technique that yields all of the observable properties of the binary spin‐bath model for magnetization transfer (MT) and demonstrate this method for in vivo studies of the human head. Based on a new model of the steady‐state behavior of the magnetization duri
## Abstract The fast spin‐echo (FSE) sequence is frequently used as a fast data‐readout technique in conjunction with other pulse sequence elements, such as in fluid‐attenuated inversion‐recovery (FLAIR) and double inversion‐recovery (DIR) sequences. In order to implement those pulse sequences, an