Quantitative determination of Gd-DTPA concentration in T1-weighted MR renography studies
✍ Scribed by Louisa Bokacheva; Henry Rusinek; Qun Chen; Niels Oesingmann; Chekema Prince; Manmeen Kaur; Elissa Kramer; Vivian S. Lee
- Publisher
- John Wiley and Sons
- Year
- 2007
- Tongue
- English
- Weight
- 168 KB
- Volume
- 57
- Category
- Article
- ISSN
- 0740-3194
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
A method for calculating contrast agent concentration from MR signal intensity (SI) was developed and validated for T~1~‐weighted MR renography (MRR) studies. This method is based on reference measurements of SI and relaxation time T~1~ in a Gd‐DTPA‐doped water phantom. The same form of SI vs. T~1~ dependence was observed in human tissues. Contrast concentrations calculated by the proposed method showed no bias between 0 and 1 mM, and agreed better with the reference values derived from direct T~1~ measurements than the concentrations calculated using the relative signal method. Phantom‐based conversion was used to determine the contrast concentrations in kidney tissues of nine patients who underwent dynamic Gd‐DTPA‐enhanced 3D MRR at 1.5T and ^99m^Tc‐DTPA radionuclide renography (RR). The concentrations of both contrast agents were found to be close in magnitude and showed similar uptake and washout behavior. As shown by Monte Carlo simulations, errors in concentration due to SI noise were below 10% for SNR = 20, while a 10% error in precontrast T~1~ values resulted in a 12–17% error for concentrations between 0.1 and 1 mM. The proposed method is expected to be particularly useful for assessing regions with highly concentrated contrast. Magn Reson Med 57:1012–1018, 2007. © 2007 Wiley‐Liss, Inc.
📜 SIMILAR VOLUMES
## Abstract ## Purpose To investigate the feasibility of the use of gadobenate dimeglumine (also known as Gd‐BOPTA) ‐enhanced T1‐weighted MR cholangiography in diagnosis of acute cholecystitis. ## Materials and Methods This prospectively designed institutional review board‐approved HIPAA‐complia
## Abstract ## Purpose To evaluate the accuracy of signal intensity (SI) analysis on unenhanced fat‐suppressed T1‐weighted MR images in the diagnosis of pancreatic disease and to compare subjective interpretation with different quantitative measurements. ## Materials and Methods The pancreas was
## Abstract ## Background The pedunculopontine nucleus (PPN) is a new promising target of deep brain stimulation (DBS) for the treatment of Parkinson's disease. This study was to develop a method of computer‐assisted automatic localization of the PPN in T1‐weighted MR images. ## Methods A 3D tem
## Abstract ## Purpose To investigate the reproducibility and transferability of texture features between MR centers, and to compare two feature selection methods and two classifiers. ## Materials and Methods Coronal T1‐weighted MR images of the knees of 63 patients, divided into three groups, w