Texture analysis for tissue discrimination on T1-weighted MR images of the knee joint in a multicenter study: Transferability of texture features and comparison of feature selection methods and classifiers

✍ Scribed by Marius E. Mayerhoefer; Martin J. Breitenseher; Josef Kramer; Nicolas Aigner; Siegfried Hofmann; Andrzej Materka


Publisher
John Wiley and Sons
Year
2005
Tongue
English
Weight
138 KB
Volume
22
Category
Article
ISSN
1053-1807

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

Purpose

To investigate the reproducibility and transferability of texture features between MR centers, and to compare two feature selection methods and two classifiers.

Materials and Methods

Coronal T1‐weighted MR images of the knees of 63 patients, divided into three groups, were included in the study. MR images were obtained at three different MR centers. Regions of interest (ROIs) were drawn in the bone marrow and fat tissue. Then texture analysis (TA) of the ROIs was performed, and the most discriminant features were identified using Fisher coefficients and POE+ACC (probability of classification error and average correlation coefficients). Based on these features, artificial neural network (ANN) and k‐nearest‐neighbor (k‐NN) classifiers were used for tissue discrimination.

Results

Although the texture features differed among the MR centers, features from one center could be successfully used for tissue discrimination in texture data on MR images from other centers. The best results were achieved using the ANN classifier in combination with features selected by POE+ACC.

Conclusion

The differences in texture features extracted from MR images from different centers seem to have only a small impact on the results of tissue discrimination. J. Magn. Reson. Imaging 2005. © 2005 Wiley‐Liss, Inc.