The quantitative determination of nucleotides from DNA modiÐed by styrene oxide is described using a combination of inductively coupled plasma high-resolution mass spectrometry (ICP-HRMS) and electrospray ionization mass spectrometry (ESI-MS), both interfaced to reversed-phase high-performance liqui
Quantitative detection of N7-(2-hydroxyethyl)guanine adducts in DNA using high-performance liquid chromatography/electrospray ionization tandem mass spectrometry
✍ Scribed by Pao-Chi Liao; Ching-Ming Li; Chien-Wen Hung; Shu-Hui Chen
- Publisher
- John Wiley and Sons
- Year
- 2001
- Tongue
- English
- Weight
- 197 KB
- Volume
- 36
- Category
- Article
- ISSN
- 1076-5174
- DOI
- 10.1002/jms.132
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
High‐performance liquid chromatography (HPLC) was combined with electrospray ionization tandem mass spectrometry (ESI‐MS/MS) to develop a sensitive and selective method for the quantitative measurement of N^7^‐(2‐hydroxyethyl)guanine (N^7^‐HEG) adducts in DNA obtained from ethylene oxide‐exposed biological samples. Selected reaction monitoring (SRM) was used as the detection mode while the fragmentation product ion at m/z 152 generated from the precursor protonated N^7^‐HEG (m/z 196) was monitored. The detection limits for N^7^‐HEG were estimated by twofold serial dilution and determined to be 4 fmol in neat standard solution and 16 fmol when a matrix effect is considered. When the mass spectrometer was operated in the selected ion monitoring mode using only the first quadrupole (without MS/MS function), the detection limits increased to 128 fmol and 1 pmol (when matrix effect is considered), respectively. A good linear correlation (R^2^ = 0.999) was observed for signal intensities obtained by injecting 16 fmol–33 pmol of N^7^‐HEG into the HPLC/ESI‐MS/MS system. Hep G2 cells were incubated for 8 h with medium containing various concentrations of ethylene oxide (ranging from 0.05 to 5.0 mM). A dose–response relationship was established, indicating that the adduct formation increases with the exposure level. The method shows potential, although the detection limit needs to be lowered for practical applications, for use in monitoring N^7^‐HEG formation in other biological systems. Copyright © 2001 John Wiley & Sons, Ltd.
📜 SIMILAR VOLUMES
A simple and sensitive method is described for the determination of E5880 in rat plasma. The method is based on high-performance liquid chromatography/electrospray ionization mass spectrometry, using deuterated E5880 as an internal standard. Selected reaction monitoring is employed for selectivity a
Liquid chromatographylmass spectrometry (LC/MS) with eleetrospray ionization has been used to analyse the nucleoside components of DNA extracted from preserved plant remains. Optimum results were obtained by use of an isOeratic ammonium acetate/acetonitrile mobile phase with post-column addition of
A method was developed for the bio-analysis of Ecteinascidin 743 (ET-743) using miniaturized liquid chromatography (LC) coupled to an electrospray ionization sample inlet (TurbolonSpray) and two quadrupole mass analyzers (LC/ESI-MS/MS). Solid-phase extraction was used as a sample pretreatment proced
## Abstract A new HPLC‐DAD‐ESI‐MS^n^ method was developed for rapid separation, characterization and quantitation of flavonoids in __Epimedium wushanense__, a popular Chinese herbal medicine. For qualitative identification, a total of 37 compounds were characterized from the underground and aerial
A validated method is described for the simultaneous analysis of PGE 2 , 11-, 12-, and 5-HETEs from cultured cells using HPLC negative electrospray ionization tandem mass spectrometry (LC/MS/MS). This method permits quantification of selected individual arachidonic acid metabolites from cell extract