𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Quantitative analysis of short echo time 1H-MRSI of cerebral gray and white matter

✍ Scribed by Mary A. McLean; Friedrich G. Woermann; Gareth J. Barker; John S. Duncan


Publisher
John Wiley and Sons
Year
2000
Tongue
English
Weight
372 KB
Volume
44
Category
Article
ISSN
0740-3194

No coin nor oath required. For personal study only.

✦ Synopsis


Quantitative analysis of (1)H-magnetic resonance spectroscopic imaging (MRSI) data was developed using the user-independent spectral analysis routine LCModel. Tissue segmentation was performed using statistical parametric mapping software (SPM 96), and the results were used to correct for cerebrospinal fluid contamination. A correction was developed for the imperfections in the spectroscopic excitation profile in order to improve the uniformity of metabolite images. After validation in phantoms, these techniques were applied to study differences in metabolite concentrations between gray and white matter in normal volunteers (n = 13). A positive correlation was found between concentration and gray matter content for most metabolites studied. The estimated ratios of metabolite concentration in gray vs. white matter were: N-acetyl aspartate + N-acetyl aspartyl glutamate (NAc) = 1.16+/- 0.11; creatine = 1.7+/-0.3; glutamate + glutamine = 2.4+/-0.5; myo-inositol = 1.6+/-0.3; choline = 0.9+/-0.2. The ratio of NAc/Cr was negatively correlated with gray matter content: gray/white = 0.69 +/-0.08. These methods will be useful in the evaluation of metabolite concentrations in MRSI voxels with mixed tissue composition in patient groups.


πŸ“œ SIMILAR VOLUMES


Robust analysis of short echo time 1H MR
✍ X. P. Zhu; K. Young; A. Ebel; B. J. Soher; L. Kaiser; G. Matson; W. M. Weiner; N πŸ“‚ Article πŸ“… 2006 πŸ› John Wiley and Sons 🌐 English βš– 225 KB

## Abstract Short echo time proton MR Spectroscopic Imaging (MRSI) suffers from low signal‐to‐noise ratio (SNR), limiting accuracy to estimate metabolite intensities. A method to coherently sum spectra in a region of interest of the human brain by appropriate peak alignment was developed to yield a

High spatial resolution 1H-MRSI and segm
✍ Susan M. Noworolski; Sarah J. Nelson; Roland G. Henry; Mark R. Day; Lawrence L. πŸ“‚ Article πŸ“… 1999 πŸ› John Wiley and Sons 🌐 English βš– 271 KB πŸ‘ 3 views

High-resolution MR imaging and spectroscopic imaging were used to study differences in proton spectra between cortical gray matter and subcortical white matter in 23 normal volunteers using a 1.5 T scanner and surface coil receivers. A point-resolved spectroscopy (PRESS) volume with an 8 x 8 x 8 pha

Cerebral White Matter in the Centrum Sem
✍ Gioacchino Tedeschi; Andrea Righini; Alberto Bizzi; Alan S. Barnett; Jeffry R. A πŸ“‚ Article πŸ“… 1995 πŸ› John Wiley and Sons 🌐 English βš– 891 KB

## Abstract Long echo time (272 ms) ^1^H magnetic resonance spectro‐scopic imaging was used to measure the relative magnitudes of the N‐acetylaspartate (NAA) signal in a variety of anatomically defined brain structures (centrum semiovale, thalamus, medial frontal cortex, and genu of the corpus call

Quantitative proton short-echo-time LASE
✍ Mohamed N.E. Kassem; Robert Bartha πŸ“‚ Article πŸ“… 2003 πŸ› John Wiley and Sons 🌐 English βš– 327 KB

## Abstract Accurate quantification of in vivo short‐echo‐time (TE) ^1^H spectra must account for contributions from both mobile metabolites and less mobile macromolecules, which can fluctuate in disease. The purpose of this study was to develop an approach for the acquisition and processing of mac

Partial-volume model for determining whi
✍ Michael C. Lee; Soonmee Cha; Susan M. Chang; Sarah J. Nelson πŸ“‚ Article πŸ“… 2006 πŸ› John Wiley and Sons 🌐 English βš– 730 KB

## Abstract ## Purpose To model the partial voluming of gray matter (GM) and white matter (WM) in perfusion imaging, and to use this model to estimate the cerebral blood volume (CBV) of pure WM and GM, which could then be used to normalize data across patients in preparation for analyzing tumor pe