๐”– Bobbio Scriptorium
โœฆ   LIBER   โœฆ

Quantitative analysis of cimetidine in human plasma using LC/APCI/SRM/MS

โœ Scribed by Keyang Xu; Vinod K. Arora; Ajai K. Chaudhary; Robert B. Cotton; Ian A. Blair


Publisher
John Wiley and Sons
Year
1999
Tongue
English
Weight
79 KB
Volume
13
Category
Article
ISSN
0269-3879

No coin nor oath required. For personal study only.

โœฆ Synopsis


A quantitative method was developed and validated for rapid and sensitive analysis of cimetidine in human plasma. The method involved the use of liquid chromatography (LC) coupled with atmospheric pressure chemical ionization (APCI) and selected reaction monitoring (SRM) mass spectrometry (MS). A cimetidine analog, SKF92374, was used as the internal standard. Separation of cimetidine and the internal standard was accomplished using a reverse-phase HPLC column (C18). The eluted components were ionized by the APCI source and subsequently detected by a highly selective triple quadrupole mass spectrometer in the SRM mode. Linear standard curves were obtained from 5 ng/mL (lower limit of quantitation) to 10,000 ng/mL. The results demonstrated excellent precision (%RSD 1.1-8.9%) and accuracy (94.7-108.0%) over this range. In addition, the amount of plasma sample needed for analysis was small (50 mL), and the plasma pretreatment (analyte recovery b94%) was simple and time saving. This assay was used to evaluate cimetidine levels in premature infants following intravenous infusion of cimetidine.


๐Ÿ“œ SIMILAR VOLUMES


Quantification of pseudoephedrine in hum
โœ Ramakrishna V. S. Nirogi; Vishwottam N. Kandikere; Manoj Shukla; Koteshwara Mudi ๐Ÿ“‚ Article ๐Ÿ“… 2007 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 213 KB

## Abstract A simple, sensitive and rapid highโ€performance liquid chromatography/positive ion electrospray tandem mass spectrometry (LCโ€MS/MS) method was developed and validated for the quantification of pseudoephedrine in human plasma using mosapride as internal standard. Following solidโ€phase ext

Development and validation of a highly s
โœ Kishore Kumar Hotha; D. Vijaya Bharathi; B. Jagadeesh; L. K. Ravindranath; K. N. ๐Ÿ“‚ Article ๐Ÿ“… 2011 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 311 KB

## ABSTRACT A highly sensitive, specific and simple LCโ€MS/MS method was developed for the simultaneous estimation of dexlansoprazole (DEX) with 50โ€‰ฮผL of human plasma using omeprazole as an internal standard (IS). The APIโ€4000 LCโ€MS/MS was operated under multiple reactionโ€monitoring mode using elect