## Abstract Some of the important features of how pulsatile flow generates artifacts in three‐dimensional magnetic resonance imaging are analyzed and demonstrated. Time variations in the magnetic resonance signal during the heart cycle lead to more complex patterns of artifacts in 3D imaging than i
Pulsatile flow artifacts in fast magnetization-prepared sequences
✍ Scribed by Talin A. Tasciyan; Donald G. Mitchell
- Publisher
- John Wiley and Sons
- Year
- 1994
- Tongue
- English
- Weight
- 745 KB
- Volume
- 4
- Category
- Article
- ISSN
- 1053-1807
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
Fast magnetization‐prepared magnetic resonance imaging sequences allow clinical acquisitions in about 1 second, with the preparation phase providing the desired contrast. Pulsatile flow artifacts, although reduced by rapid acquisition, can degrade image quality. The authors explore the causes of aortic pulsatile flow artifacts in inversion‐recovery‐prepared acquisitions of the abdomen, taking into consideration various parameters. The flow signal within an 8‐mm‐thick section was simulated and subsequently Fourier transformed to determine the location and extent of flow artifacts. Results of simulations were validated with abdominal images of human subjects. Recording all encodings within one cardiac cycle reduced pulsatile flow artifacts in nonsegmented acquisitions with sequential phase‐encoding order, regardless of the location of magnetization preparation within the cardiac cycle. In segmented acquisitions, however, the sequential order always increased flow artifacts. To reduce the artifacts in short TI acquisitions, the magnetization should be prepared during diastole. In clinical acquisitions, flow artifacts were further reduced by modifying the phase‐encoding scheme.
📜 SIMILAR VOLUMES
## Abstract We present an analysis of how flow oblique to the frequency‐encoding direction generates displacement artifacts in MR imaging and show that for flow which has constant velocity between the start of the phase encoding and the center of the echo it is possible to eliminate these artifacts
## Abstract It has been observed that fast spin‐echo (FSE) images with a large field of view (>40 cm) in certain directions exhibit unusual ghosting artifacts that cannot be eliminated with existing ghost removal methods. These artifacts have been related to a higher‐order magnetic field perturbati
A method for estimating pressure gradients from MR images is demonstrated. Making the usual assumption that the flowing medium is a Newtonian fluid, and with appropriate boundary conditions, the inertial forces (or acceleration components of the flow) are proportional to the pressure gradients. The
## Abstract Velocity spectra can be derived from velocity‐encoded nuclear magnetic resonance (NMR) images. Velocity spectra are histograms showing the amounts of fluid flowing at different velocities in the sensitive volume of the measurement. Velocity spectra may prove to be useful in characterizi
A method for the contrast enhancement and reduction of artifacts in three-dimensional (3D) magnetization-prepared (MP) magnetic resonance angiography (MRA) sequences is presented. A common artifact in these sequences is a periodical signal loss inside the vessels at the slab-slab junctions due to pr