Pulsatile flow artifacts in 3D magnetic resonance imaging

✍ Scribed by Lawrence R. Frank; Richard B. Buxton; Charles W; Kerber


Publisher
John Wiley and Sons
Year
1993
Tongue
English
Weight
954 KB
Volume
30
Category
Article
ISSN
0740-3194

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

Some of the important features of how pulsatile flow generates artifacts in three‐dimensional magnetic resonance imaging are analyzed and demonstrated. Time variations in the magnetic resonance signal during the heart cycle lead to more complex patterns of artifacts in 3D imaging than in 2D imaging. The appearance and location of these artifacts within the image volume are shown to be describable as displacements along a line in a plane parallel to that defined by the phase and volume encode directions. The angle of the line in the plane depends solely upon the imaging parameters while the ghost displacement along the line is proportional to the signal modulation frequency. Aliasing of these ghosts leads to a variety of artifact patterns which are sensitive to the pulsation period and repetition time of the pulse sequence. Numerical simulations of these effects were found to be in good agreement with experimental images of an elastic model of a human carotid artery under simulated physiological conditions and with images of two human subjects.


πŸ“œ SIMILAR VOLUMES


Elimination of oblique flow artifacts in
✍ Lawrence R. Frank; Adrian P. Crawley; Richard B. Buxton πŸ“‚ Article πŸ“… 1992 πŸ› John Wiley and Sons 🌐 English βš– 641 KB

## Abstract We present an analysis of how flow oblique to the frequency‐encoding direction generates displacement artifacts in MR imaging and show that for flow which has constant velocity between the start of the phase encoding and the center of the echo it is possible to eliminate these artifacts

Pulsatile flow artifacts in fast magneti
✍ Talin A. Tasciyan; Donald G. Mitchell πŸ“‚ Article πŸ“… 1994 πŸ› John Wiley and Sons 🌐 English βš– 745 KB

## Abstract Fast magnetization‐prepared magnetic resonance imaging sequences allow clinical acquisitions in about 1 second, with the preparation phase providing the desired contrast. Pulsatile flow artifacts, although reduced by rapid acquisition, can degrade image quality. The authors explore the

Analysis of spin-echo rephasing with pul
✍ J. Katz; R. M. Peshock; P. McNamee; S. Schaefer; C. R. Malloy; R. W. Parkey πŸ“‚ Article πŸ“… 1987 πŸ› John Wiley and Sons 🌐 English βš– 700 KB

The effects of pulsatile flow on spin phases in spin-echo magnetic resonance imaging are considered. General expressions for the spin phases of the first four echoes are derived in terms of the Fourier coefficients of flow. These expressions are valid for any timedependent acceleration and, hence, a

Artifacts in functional magnetic resonan
✍ Sandra Bates; Zerrin Yetkin; Andre Jesmanowicz; James S. Hyde; Peter A. Bandetti πŸ“‚ Article πŸ“… 1995 πŸ› John Wiley and Sons 🌐 English βš– 327 KB

## Abstract Unexpectedly large fluctuations in signal intensity wen identified in the functional MRI (FMRI) of normal subjects breathing pure oxygen intermittently. To test the hypothesis that the signal changes were due to fluctuating concentrations of gaseous (paramagnetic) oxygen in the magnetic

Measurement of flow field in biofilm rea
✍ Kevin P. Nott; Frank P. Heese; Laurance D. Hall; Lynne E. Macaskie; Marion Pater πŸ“‚ Article πŸ“… 2005 πŸ› American Institute of Chemical Engineers 🌐 English βš– 317 KB πŸ‘ 2 views

## Abstract 3‐D Magnetic resonance imaging (MRI) was used to measure the flow field of water in a packed‐bed column containing Serratia sp. biofilm supported on polyurethane foam, and subsequently to follow a reaction which precipitates lanthanum phosphate on the biofilm. Sensitizing the MR image c