𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Preparation of thick-film glass capillary columns by the dynamic coating procedure

✍ Scribed by M. Novotný; K.D. Bartle


Publisher
Elsevier Science
Year
1974
Tongue
English
Weight
539 KB
Volume
93
Category
Article
ISSN
1873-3778

No coin nor oath required. For personal study only.

✦ Synopsis


The capacity for non-polar stationary phases of the silanized inner surfaces of glass capillary columns is shown to be restricted to a 2-3 x IO-' m thick film. However, geometrical modification of a soda-glass surface by etching with NC1 gas before silanization allows non-polar silicone-oil films to be prepared with average thickness (in good agreement with those predicted from the Fairbrother-Stubbs relation) as high as 14x 10" m. Such films are stable even after conditioning at 190", and the column efficiencies, near 3000 theoretical plates per meter, were maintained. Van Deemter plots are similar for columns with average film thicknesses between 1 and 14 x 10" m, thus suggesting that the surface developed through the geometrical modification is still covered with a relatively thin film of stationary phase.


📜 SIMILAR VOLUMES


The preparation of thick-film glass capi
✍ Torline, P. ;du Plessis, G. ;Schnautz, N. ;Thompson, J. C. 📂 Article 📅 1979 🏛 John Wiley and Sons 🌐 English ⚖ 354 KB 👁 1 views

## Abstract A detailed method for the routine preparation of glass capillary columns is presented. The method consists of coating a glass tube with quartz powder prior to pulling the tube into a capillary. The inner surface of the capillary consists of an even distribution of quartz particles fused

Preparation of apolar glass capillary co
✍ Grob, K. ;Grob, G. ;Grob, K. 📂 Article 📅 1978 🏛 John Wiley and Sons 🌐 English ⚖ 520 KB

## Abstract As an extension of previous reports, the barium carbonate procedure has been optimized in detail for the preparation of apolar columns. The aim was to produce optimum overall column characteristics, and to maintain them unchanged under the prolonged influence of the highest possible tem

On the efficiency of capillary columns c
✍ David, F. ;Proot, M. ;Sandra, P. 📂 Article 📅 1985 🏛 John Wiley and Sons 🌐 English ⚖ 435 KB 👁 1 views

The efficiency of FSOT columns coated with thick films of polyphenylmethylsiloxane was theoretically and experimentally compared to thin apolar and medium polar coatings and to thick apolar coatings. Experimental hli and TZG plots clearly demonstrate the enormous loss in chromatographic efficiency o