Preparation of glucose oxidase immobilized in different carriers using radiation polymerization
β Scribed by KS Atia; AI El-Batal
- Publisher
- Wiley (John Wiley & Sons)
- Year
- 2005
- Tongue
- English
- Weight
- 126 KB
- Volume
- 80
- Category
- Article
- ISSN
- 0268-2575
No coin nor oath required. For personal study only.
β¦ Synopsis
Abstract
Glucose oxidase (EC 1.1.3.4) was immobilized on different polymeric materials using different immobilization techniques (entrapping by Ξ³βirradiation, and covalent binding using epichlorohydrin). Studies were carried out to increase the thermal stability of glucose oxidase (GOD) for different applications. The activity and stability of the resulting biopolymers have been compared with those of free GOD. The effect of different polyvinyl alcohol/polyacrylamide (PVA/PAAm) compositions of the copolymer carrier on the enzymatic activity of the immobilized GOD was studied. The maximum enzymatic activity was obtained with the composition ratio of PVA/PAAm of 60:40. The behaviour of the free and immobilized enzyme was analysed as a function of pH. A broadening in the pH profile (5.5β8) was observed for immobilized preparations. The activity and stability of the resulting biopolymers produced by immobilization of GOD onto different carriers have been compared, in both aqueous and organic media, with those of the free GOD. The enzyme's tolerance toward both heat and organic solvent was enhanced by immobilization onto polymers. The addition of different concentrations of organic solvents (10β50%, v/v) to the enzyme at higher temperature (60 Β°C) was found to stabilize the enzyme molecule. The strongest stabilizing effect on the enzymatic activity was achieved at a concentration of 10%. Copyright Β© 2005 Society of Chemical Industry
π SIMILAR VOLUMES
An immobilized glucose oxidase (GOD) membrane has been prepared by enclosing GOD within a Millipore (MP) filter, both sides of which were coated with plasma-polymerized propargyl alcohol (PPPA). The membrane was mounted over an amperometric oxygen electrode to compose a glucose sensor that was furth
Enzymatic metallized carbon paste electrodes prepared by incorporation of mixtures of different metals into the paste offer a substantial decrease in the overvoltage for hydrogen peroxide oxidation and reduction. Dramatic improvements in the sensitivity and selectivity for glucose determination were
A flow-injection system with anodic aniperometric detection for glucose determination in human blood serum samples was optimized by a comparison of various arrangements of enzyme immobilization and the elimination o f interferences. The best results were obtained using a compact membrane biosensor i