𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Prediction of the remaining lifetime of stainless steels under conditions of stress corrosion cracking

✍ Scribed by M. Tandler; L. Vehovar; V. Doleček; U. Rotnik


Publisher
John Wiley and Sons
Year
2003
Tongue
German
Weight
251 KB
Volume
54
Category
Article
ISSN
0947-5117

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

The prediction of the lifetime of metal structures and equipment under conditions of stress corrosion is very complicated because of the complexity of this process of degradation. Recently a new method, based on the so‐called corrosion elongation curves, has been found, which can be used to predict the time to failure under these conditions. By upgrading of these curves (and thus obtaining Upgraded Corrosion Elongation Curves – UCEC's) it has been possible to obtain a precise definition of the time needed for the initiation of the corrosion crack, and for its stable growth. It is upon this basis that diagrams for the prediction of remaining lifetime (DPRL's) have been developed. DPRL's can also be used to predict the values of various critical parameters which have to be achieved if a stress corrosion crack is to occur.


📜 SIMILAR VOLUMES


Environmental aspects of stress corrosio
✍ Ing. B. Eremi; V. A. Maričev 📂 Article 📅 1979 🏛 John Wiley and Sons 🌐 German ⚖ 323 KB 👁 1 views

## Abstract Stress corrosion crack velocity and stress corrosion threshold stress intensity have been measured for 18Cr–10Ni–0,5Ti stainless steel in relation to environmental variations. These studies showed that both stage I and stage II growth rate dependence on K are influenced by environmental

Determination of corrosion-assisted stre
✍ A. Díaz-Sánchez; V. M. Castaño 📂 Article 📅 2007 🏛 John Wiley and Sons 🌐 German ⚖ 209 KB 👁 1 views

The corrosion assisted stress crack growth rate of 304L stainless steel welds, was determined by the rising displacement test method. The experiments were carried out in a Boiling Water Reactor (BWR) environment, using a refreshed autoclave loop system at 288 C and 8 MPa of pressure. Pre-fatigued CT

On the resistance of duplex steel to str
✍ Prof. Dr.-Ing. Vladimír Číhal 📂 Article 📅 1992 🏛 John Wiley and Sons 🌐 German ⚖ 457 KB 👁 1 views

## Abstract The paper gives the results of tests carried out into the stress corrosion cracking in duplex stainless steel (Type 02Cr22Ni5Mo3N, W.Nr. 1.4462); this grade is characterized by high resistance to intergranular corrosion, while resistance to stress corrosion cracking may be impaired by t

Performance of galvanized and stainless
✍ V. Saraswathy; Ha-Won Song 📂 Article 📅 2005 🏛 John Wiley and Sons 🌐 German ⚖ 227 KB 👁 1 views

In the recent past, the damage caused by rebar corrosion in concrete structures has been considered as one of the major durability problems affecting the service life of concrete structures. In order to prevent corrosion of steel reinforcement, various types of protective methods have been adopted.