Abstract
BACKGROUND: The hydrodynamic conditions of a surface aeration system can be characterized by interpreting the power consumption of the impeller. Power consumed by aeration tanks depends on the geometries of the impeller and tank, which is generally denoted by the power number.
RESULTS: The various geometric and dynamic parameters affecting the power number have been studied experimentally. Three flatโbottomed cylindrical tanks of 1, 0.518 and 0.168 m^2^ cross sectional area, fitted with six flat bladed impellers were used as baffled and unbaffled circular tanks.
CONCLUSIONS: Scaleโup criteria have been developed for baffled surface aeration tanks. General correlations have been developed for both baffled and unbaffled aeration systems which are useful in the design of surface aeration tanks. Copyright ยฉ 2010 Society of Chemical Industry
๐ SIMILAR VOLUMES
The energy loss characteristics of sealed-end parallel flow hollow fiber membrane aerators were evaluated in this study. The membrane aerators were used successfully to oxygenate water without producing bubbles. Typically, a membrane aerator consists of a large number of sealed-end fibers in an exte
## Abstract Aeration experiments were conducted in different sized baffled and unbaffled circular surface aeration tanks to study their relative performance on oxygen transfer process while aerating the same volume of water. Experiments were carried out with the objective of ascertaining the effect
## Abstract Power characteristics of an unbaffled aerated agitated vessel with unsteadily forwardโreverse rotating impellers, ie a new type of gasโliquid agitator named โAJITERโ, treating viscous Newtonian liquids were studied experimentally. Measurements were first made on the agitation torque, ie
## Abstract Oxygen transfer rate and the corresponding power requirement to operate the rotor are vital for design and scaleโup of surface aerators. Present study develops simulation or scaleโup criterion correlating the oxygen transfer coefficient and power number along with a parameter governing